Maintenance and Troubleshooting
2
10004
Output_overload
3
11000
Bat over-voltage
0
alarm
11000
Bat under-voltage
1
alarm
output_overload_
11000
2
alarm
11000
abnormal_temperatur
3
e_sensor
11000
dc_power_alarm
4
11000
battery_stops_
5
running_alarm
whether the wiring is correct.
2.Restart the inverter to see if the fault still
exists. If it still exists, please call the service
center.
1.
Check whether the load exceeds the
rated power.
2.
Restart the inverter to see if the fault still
exists. Ifit still exists, please call the service
center.
Check that the actual battery voltage is
10V higherthan the battery charging cut-
off voltage
Check that the actual battery voltage is
10V higherthan the battery discharging
cut-off voltage
Check whether the load exceeds 0.95 of
the ratedpower
Restart the inverter to see if the fault still
exists. Ifit still exists, please call the service
center.
1. Check whether the total power of the
batteryand PV is less than the load power.
2. Restart the inverter to see if the fault still
exists.If it still exists, please call the service
center.
1. If the battery is not connected, use a
multimeterto measure whether there is
voltage at the battery terminal.
2. Restart the inverter to see if the fault still
exists.If it still exists, please call the service
center.