Module/Channel Parameters - Siemens SIMATIC 6DL1 136-6AA00-0PH1 Manual

F-ai 8xi 2-/4-wire hart ha i/o module
Table of Contents

Advertisement

5.3

Module/channel parameters

Definition
Module/channel parameters are specific parameters whose configuration can affect the entire
module or channels.
Description
The parameters of the I/O module are displayed in the "Properties" dialog of the module in HW
Config on the following tabs:
• "Parameters" tab
• "Redundancy" tab
This tab is displayed for redundant I/O modules.
The following module/channel parameters are available.
"Parameters" tab
Parameter
F-parameters
F_source_address
(Page 27)
F_destination_address
(Page 27)
F_monitoring time (ms)
(Page 28)
Cross-channel
Cross-channel parameters act on all identically named parameters of the channels of the module and thus allow a higher-level
setting.
Measurement type
(Page 31)
Measuring range
(Page 31)
Smoothing (Page 29)
Diagnostics wire break
(Page 32)
F-AI 8xI 2-/4-wire HART HA
Equipment Manual, 09/2021, A5E50557845-AA
Value range
1 (display only)
a
1 to 65534
10 ms to 65535 ms
deactivated
2‑wire
4‑wire
0..20mA
4..20mA
1 (none)
4
16
64
deactivated
activated
5.3 Module/channel parameters
Default
Re-parame‐
terization in
RUN
1
No
Preset automatically
No
b
2500
No
2‑wire
No
4..20mA
No
1
No
activated
No
Parameters/address space
Efficiency range
Module
Module
Module
Channel
Channel
Channel
Channel
23

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simatic et 200sp ha

Table of Contents