Siemens SIMATIC ET 200SP HA Equipment Manual

Siemens SIMATIC ET 200SP HA Equipment Manual

Distributed i/o devices busadapter for distributed i/o
Hide thumbs Also See for SIMATIC ET 200SP HA:

Advertisement

SIMATIC
Distributed I/O devices
BusAdapter for Distributed I/O
Equipment Manual
Valid for ET 200SP HA and Compact Field Unit
09/2019
A5E39261458-AB
Security information
Special conditions for safe
use of the BusAdapter
Preface
Installation
Maintenance
Diagnostics
Pin assignments
Technical specifications
Contact
1
2
3
4
5
6
A
B
C

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIMATIC ET 200SP HA

  • Page 1 Security information Special conditions for safe use of the BusAdapter Preface SIMATIC Installation Distributed I/O devices BusAdapter for Distributed I/O Maintenance Diagnostics Equipment Manual Pin assignments Technical specifications Contact Valid for ET 200SP HA and Compact Field Unit 09/2019 A5E39261458-AB...
  • Page 2 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Table Of Contents

    Table of contents Security information............................5 Special conditions for safe use of the BusAdapter ..................7 Preface ...............................11 Installation ..............................13 Connections on the interface module and the BusAdapter............13 Connecting a BusAdapter to the PROFINET IO system............13 BusAdapter BA 2xFC ......................14 BusAdapter BA 2xLC ......................18 BusAdapter BA 2xRJ45 ......................21 BusAdapter BA LC/FC ......................23 BusAdapter BA LC/RJ45......................24...
  • Page 4 Table of contents BusAdapter for Distributed I/O Equipment Manual, 09/2019, A5E39261458-AB...
  • Page 5: Security Information

    Siemens’ products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used. Use of product versions that are no longer supported, and failure to apply the latest updates may increase customer’s exposure to cyber...
  • Page 6 Security information BusAdapter for Distributed I/O Equipment Manual, 09/2019, A5E39261458-AB...
  • Page 7: Special Conditions For Safe Use Of The Busadapter

    Special conditions for safe use of the BusAdapter Introduction The I/O system in which the BusAdapters are to be used must be installed in a suitable enclosure which ensures at least IP 54 degree of protection according to EN 60529. Use a safety enclosure that meets the requirements regarding spread of fire and exhibits an appropriate strength according to UL61010-1 and UL61010-2-201.
  • Page 8 Special conditions for safe use of the BusAdapter WARNING Safety functional extra low voltage Make sure that the supply and input voltages of the IO system are generated safely separately (Nominal value: 24 V DC +-20% Power supply according to the following standards: ●...
  • Page 9 Special conditions for safe use of the BusAdapter WARNING Explosion hazard If the electric circuit is live, the following must be observed: ● Do not disconnect the device in a flammable or combustible atmosphere. ● Do not open the housing in a flammable or combustible atmosphere. WARNING Area of application This device is suitable for use in environments of Class 1, Division 2, Groups A, B, C, D;...
  • Page 10 Special conditions for safe use of the BusAdapter BusAdapter for Distributed I/O Equipment Manual, 09/2019, A5E39261458-AB...
  • Page 11: Preface

    You can find information about the electrical and optical networks (including cables and cable lengths) in the system manual "SIMATIC NET; Industrial Ethernet / PROFINET; Passive Network Components (https://support.industry.siemens.com/cs/ww/en/view/84922825)". Validity of the documentation This documentation applies to the following products: ●...
  • Page 12 ● Information about the technical support available can be found in the appendix to this documentation (http://www.siemens.com/simatic-tech-doku-portal). ● The technical documentation for the individual SIMATIC products and systems is available on the Internet (https://mall.industry.siemens.com). ● The online catalog and the ordering system are available on the Internet (https:// mall.industry.siemens.com).
  • Page 13: Installation

    Installation Connections on the interface module and the BusAdapter The following figure shows the connections on the interface module and the BusAdapter in schematic form. Connecting a BusAdapter to the PROFINET IO system Installing a PROFINET cable on the BusAdapter Depending on the configuration of the PROFINET IO system, you select electrical or optical PROFINET IO cables for the connection of the distributed I/O.
  • Page 14: Busadapter Ba 2Xfc

    Additional information ● You can find information on the bus cables in the system manual SIMATIC NET Industrial Ethernet / PROFINET Passive Network Components (https:// support.industry.siemens.com/cs/ww/en/view/84922825) ● Refer to the specifications in the "PROFINET Installation Guide (http://www.profibus.com)". BusAdapter BA 2xFC Introduction...
  • Page 15 Installation 4.3 BusAdapter BA 2xFC Required tools Screwdriver: ● TORX T10 ● 3.5 mm blade width Required accessories ● If you are using FastConnect cables, we recommend you use the Industrial Ethernet FastConnect stripping tool (6GK1901‑1GA00) with blade cassette green (6GK1901‑1B...). This guarantees fast and safe stripping.
  • Page 16 Installation 4.3 BusAdapter BA 2xFC Installing a BusAdapter to distributed I/O To connect the PROFINET IO to the device via the BusAdapter BA 2xFC, proceed as directed in the following figures: Table 4-1 Objects in the figures Object Marking in the figures Locking slide Wire guide Shield contact...
  • Page 17 A data transfer point is prescribed for connection to the WAN (Wide Area Network) that guarantees this degree of safety. Additional information ● System manual "SIMATIC NET; Industrial Ethernet / PROFINET; Passive Network Components (https://support.industry.siemens.com/cs/ww/en/view/84922825)" ● Pin assignment of the FC outlet (4-pin connector) (Page 32) BusAdapter for Distributed I/O Equipment Manual, 09/2019, A5E39261458-AB...
  • Page 18: Busadapter Ba 2Xlc

    Installation 4.4 BusAdapter BA 2xLC BusAdapter BA 2xLC Introduction Plug Front view Description ① LED LK 1 - Status of Ethernet connection port 1 ② LED LK 2 - Status of Ethernet connection port 2 You can find information on this in section "Diagnostics via LED displays (Page 29)".
  • Page 19 "SIMATIC NET; Industrial Ethernet / PROFINET; Passive Network Components (https:// support.industry.siemens.com/cs/ww/en/view/84922825)". ● If the device is the last node of the FOC network, you need to terminate the unoccupied FOC interface with a blanking plug. When the modules ship, the blanking plugs are inserted in the PROFINET sockets of the BusAdapter.
  • Page 20 Connecting a PROFINET IO cable to the device via BusAdapter BA 2×LC Additional information You can find information about the installation guidelines and installation of fiber optic cables in the documentation "SIMATIC NET; Industrial Ethernet / PROFINET; Passive Network Components (https://support.industry.siemens.com/cs/ww/en/view/84922825)". BusAdapter for Distributed I/O Equipment Manual, 09/2019, A5E39261458-AB...
  • Page 21: Busadapter Ba 2Xrj45

    You can find information on this in the system manual "SIMATIC NET; Industrial Ethernet / PROFINET; Passive Network Components (https://support.industry.siemens.com/cs/ww/en/ view/84922825)". Installing a BusAdapter to distributed I/O To connect PROFINET IO to the device via the BusAdapter BA 2×RJ45, proceed as follows: 1.
  • Page 22 Installation 4.5 BusAdapter BA 2xRJ45 Installing BusAdapter BA 2×RJ45 Note The figure below is a basic representation using the ET 200SP HA as an example; it is also valid for other distributed I/O devices. ① BusAdapter BA 2×RJ45 ② RJ45 connector ③...
  • Page 23: Busadapter Ba Lc/Fc

    Installation 4.6 BusAdapter BA LC/FC BusAdapter BA LC/FC Introduction Plug Front view Description ① LED LK 1 - Status of Ethernet connection port 1 ② LED LK 2 - Status of Ethernet connection port 2 You can find information on this in section "Diagnostics via LED displays (Page 29)".
  • Page 24: Busadapter Ba Lc/Rj45

    Information on SIMATIC BusAdapter BA 2xRJ45VD HA (6GK5991-2VA00-8AA2) You can find technical specifications and additional information about this BusAdapter in the Internet: SIMATIC NET; Industrial Ethernet / PROFINET; Passive Network Components (https:// support.industry.siemens.com/cs/ww/en/view/109759611) BusAdapter for Distributed I/O Equipment Manual, 09/2019, A5E39261458-AB...
  • Page 25 Installation 4.8 BusAdapter 2xRJ45VD HA Plug Front view Description ① LED LK 1 - Status of Ethernet connection port 1 ② LED without function ③ LED LK 2 - Status of Ethernet connection port 2 ④ LED without function You can find information on this in section "Diagnostics via LED displays (Page 29)".
  • Page 26 Installation 4.8 BusAdapter 2xRJ45VD HA BusAdapter for Distributed I/O Equipment Manual, 09/2019, A5E39261458-AB...
  • Page 27: Maintenance

    Maintenance Exchanging the BusAdapter or interface of the distributed I/O The device name of the distributed I/O device is saved at the following locations when transferring the device name to the distributed I/O: ● In the BusAdapter ● In the interface of the distributed I/O device (e.g. interface module or I/O device itself) Note Replacing a BusAdapter (removing/inserting) Removing/inserting the BusAdapter under voltage is prohibited.
  • Page 28 Maintenance 5.1 Exchanging the BusAdapter or interface of the distributed I/O BusAdapter for Distributed I/O Equipment Manual, 09/2019, A5E39261458-AB...
  • Page 29: Diagnostics

    Diagnostics Diagnostics via LED displays Below, you will find tables containing information on the status and error messages on the BusAdapter. LEDs on the BusAdapter The following LEDs are located on the front of the BusAdapter. Marking Color Meaning ① Green LED displays on the BusAdapter to visualize the status of the ②...
  • Page 30 Diagnostics 6.1 Diagnostics via LED displays Connection setup Note Connection configuration with BusAdapter BA 2xRJ45VD HA for long cable lengths It can take up to 2 minutes to establish a connection with the maximum permissible cable length of 500 m. BusAdapter for Distributed I/O Equipment Manual, 09/2019, A5E39261458-AB...
  • Page 31: Pin Assignments

    Pin assignments Pin assignment of the RJ45 connection plug Table A-1 Pin assignment of the RJ45 connector View RJ45‑plug socket Contact assignment TD (Transmit Data +) TD_N (Transmit Data –) RD (Receive Data +) Ground Ground RD_N (Receive Data –) Ground Ground Core pair...
  • Page 32: Pin Assignment Of The Fc Outlet (4-Pin Connector)

    Pin assignments A.3 Pin assignment of the FC outlet (4-pin connector) Note Shield support and lightning protection design If you connect a BA 2xRJ45VD HA BusAdapter to existing PROFIBUS cabling, the same specifications regarding shielding and lightning protection concept apply as for PROFIBUS. Pin assignment of the FC outlet (4-pin connector) Table A-3 Pin assignment of the FC outlets...
  • Page 33: Technical Specifications

    Technical specifications Ambient conditions Information on the documentation Note Higher-priority documentation The information for the specific components takes precedence over the information in this documentation. The statements in the product information always takes precedence over all other information. Use in hazardous area Read section "Special conditions for safe use of the BusAdapter (Page 7)".
  • Page 34 Technical specifications B.1 Ambient conditions Ambient conditions Permissible range Comments Concentration of ● SO : <0.5 ppm Test: 10 ppm; 4 days pollutants Test: 1 ppm; 4 days ● RH: <60%, no condensation ● H S: <0.1 ppm ● RH: <60%, no condensation ISA-S71.04 severity level G1;...
  • Page 35: Simatic Busadapter Ba 2Xrj45 (6Dl1193-6Ar00-0Aa0)

    Technical specifications B.2 SIMATIC BusAdapter BA 2xRJ45 (6DL1193-6AR00-0AA0) SIMATIC BusAdapter BA 2xRJ45 (6DL1193-6AR00-0AA0) Article number 6DL1193-6AR00-0AA0 General information Product type designation BA 2x RJ45 Interfaces Number of PROFINET interfaces 1; 2 ports (switch) RJ45 Supports protocol for PROFINET IO ● Number of RJ45 ports Cable length 100 m –...
  • Page 36: Simatic Busadapter Ba Lc/Rj45 (6Dl1193-6Ag20-0Aa0)

    Technical specifications B.3 SIMATIC BusAdapter BA LC/RJ45 (6DL1193-6AG20-0AA0) SIMATIC BusAdapter BA LC/RJ45 (6DL1193-6AG20-0AA0) Article number 6DL1193-6AG20-0AA0 General information Product type designation BA LC/RJ45 Interfaces Number of PROFINET interfaces 1; 2 ports (switch) LC / RJ45 Supports protocol for PROFINET IO ●...
  • Page 37: Simatic Busadapter Ba 2Xlc (6Dl1193-6Ag00-0Aa0)

    Technical specifications B.4 SIMATIC BusAdapter BA 2xLC (6DL1193-6AG00-0AA0) SIMATIC BusAdapter BA 2xLC (6DL1193-6AG00-0AA0) Article number 6DL1193-6AG00-0AA0 General information Product type designation BA 2xLC Interfaces Number of PROFINET interfaces 1; 2 ports (switch) LC Multimode Glass Fibre Supports protocol for PROFINET IO ●...
  • Page 38: Simatic Busadapter Ba Lc/Fc (6Dl1193-6Ag40-0Aa0)

    Technical specifications B.5 SIMATIC BusAdapter BA LC/FC (6DL1193-6AG40-0AA0) SIMATIC BusAdapter BA LC/FC (6DL1193-6AG40-0AA0) Article number 6DL1193-6AG40-0AA0 General information Product type designation BA LC/FC Interfaces Number of PROFINET interfaces 1; 2 ports (switch) LC / FC Supports protocol for PROFINET IO ●...
  • Page 39: Simatic Busadapter Ba 2Xfc (6Dl1193-6Af00-0Aa0)

    Technical specifications B.6 SIMATIC BusAdapter BA 2xFC (6DL1193-6AF00-0AA0) SIMATIC BusAdapter BA 2xFC (6DL1193-6AF00-0AA0) Article number 6DL1193-6AF00-0AA0 General information Product type designation BA 2xFC Interfaces Number of PROFINET interfaces 1; 2 ports (switch) FC Supports protocol for PROFINET IO ● Number of FC (FastConnect) connections Cable length 100 m –...
  • Page 40 Technical specifications B.6 SIMATIC BusAdapter BA 2xFC (6DL1193-6AF00-0AA0) BusAdapter for Distributed I/O Equipment Manual, 09/2019, A5E39261458-AB...
  • Page 41: Contact

    Contact Department Contact Repair service Siemens AG Repair Service Facility Digital Industries Factory Automation Operative Q functions DI FA MF EWA QM 31 Mr. Alexander Luber Werner-von-Siemens-Str. 50 92224 Amberg Germany Tel.: +49 9621 80-3447 Manufacturer Siemens AG Digital Industries...
  • Page 42 Contact BusAdapter for Distributed I/O Equipment Manual, 09/2019, A5E39261458-AB...
  • Page 43: Index

    Index Ambient conditions Technical specifications Climatic, 33 Climatic ambient conditions, 33 BusAdapter BA 2xLC, 18 BA 2×FC, 14 BA LC/FC, 23 Connect BA 2xRJ45, 21 Connect BusAdapter RJ45 HA, 25 Connecting BA LC/RJ, 24 Climatic ambient conditions, 33 Connecting BA 2xRJ45 on interface module, 21 BA RJ45VD HA to interface module, 25 BA 2×FC on the interface module, 14 BA 2×LC on the interface module, 18...
  • Page 44 Index BusAdapter for Distributed I/O Equipment Manual, 09/2019, A5E39261458-AB...

Table of Contents