5 Measuring chamber

The measuring chamber can be removed and disassembled when required to do so.
This section describes the steps for doing so.
Note: If the meter is under pressure, pressure must be turned off and relieved
before chamber bolts are loosened or removed!
Required tools
2.5, 3, and 6mm hex head ball end drivers (6mm not needed for the R2)
Sensus seal screw tool—for bonnet removal
Open end/box wrenches as determined by size and type of OMNI meter
7/16"x1/2" open end/box wrench
9/16" x 5/8" open end/box wrench
3/4" x 11/16" open end/box wrench
15/16" open end/ box wrench
Assembly grease
5 Measuring chamber | 18