  • Page 1 Installation, Operation, and Maintenance Manual 885939_5.0 CCD 301...
  • Page 3 Notes Notes • The modem is designed to be used with Xylem Cloud Services only and not as a stand-alone modem. • Xylem reserves the right to remotely upgrade the software and configuration files in the modem. It is the Purchaser’s responsibility to ensure that the modem is connected at all times to enable such upgrades.
  • Page 5: Table Of Contents

    Table of Contents Table of Contents 1 Introduction and Safety.................... 2 1.1 Introduction......................2 1.2 Safety terminology and symbols..............2 1.3 User safety......................3 1.3.1 Power lock-out................... 4 1.3.2 Qualification of personnel................ 4 1.4 End of life product disposal................4 1.5 Spare parts......................
  • Page 6: Introduction And Safety

    This includes any modification to the equipment or use of parts not provided by Xylem. If there is a question regarding the intended use of the equipment, please contact a Xylem representative before proceeding.
  • Page 7: User Safety

    1 Introduction and Safety Hazard levels Hazard level Indication A hazardous situation which, if not avoided, will DANGER: result in death or serious injury A hazardous situation which, if not avoided, could WARNING: result in death or serious injury A hazardous situation which, if not avoided, could CAUTION: result in minor or moderate injury Notices are used when there is a risk of equipment...
  • Page 8: Power Lock-Out

    Risk of electrical shock or burn. A certified electrician must supervise all electrical work. Comply with all local codes and regulations. All work on the product must be carried out by certified electricians or Xylem authorized mechanics. Xylem disclaims all responsibility for work done by untrained, unauthorized personnel.
  • Page 9: Spare Parts

    1.6 Warranty For information about warranty, see the sales contract. 1.7 Support Xylem only supports products that have been tested and approved. Xylem does not support unapproved equipment. CCD 301 Installation, Operation, and Maintenance Manual...
  • Page 10: Product Description

    2 Product Description 2 Product Description 2.1 Product design CCD 301 is a wireless unit that is used in pumping stations. The unit sends data over the General Pack Radio Service (GPRS), 2G, or 3G network. The unit allows remote monitoring and data collection from any location. 2.2 Parts Figure 1: CCD301, part number 803 49 00 Part...
  • Page 11: Extra Parts

    2 Product Description 2.3 Extra parts Part number Item Description 803 98 00 RS-232 communication Connects the FGC pump controller to the unit and power cable 815 20 00 RS-485 communication Connects the SRC 311 pump drive or a data cable splitter cable to the unit 83 84 43...
  • Page 12: Installation

    3 Installation 3 Installation 3.1 Connection and configuration: Alarm management 3.1.1 Precautions Before starting work, make sure that the safety instructions have been read and understood. DANGER: Electrical Hazard Before starting work on the unit, make sure that the unit and the control panel are isolated from the power supply and cannot be energized.
  • Page 13: Requirements

    3. Select one of the following steps to connect a device to the unit. For more information about the devices that connect with the unit, go to the support site at xylem.com/avensor. – Connect the RS-232 cable from the pump controller to the terminals.
  • Page 14 3 Installation RS-232 Signal lead color Unit terminal White Rx, RTU Tx Green Tx, RTU Rx Yellow Ground (earth) – Connect the RS-485 cable from the pump drive to the terminals. RS-485 Signal lead color Unit terminal Brown White or brown White or green Ground (earth) –...
  • Page 15: Check The Mobile Connection

    5. Turn on the power of the equipment and if necessary, the separate power supply. 6. Configure the connected devices. For more information, go to the support site at xylem.com/avensor. 7. Turn on the unit. 3.3 Check the mobile connection The unit is turned on.
  • Page 16 3 Installation State Description Blinks red Searches for the network Solid green Good signal strength Solid red Medium signal strength Unlit Low signal strength 2. If the signal strength is too low, move the external antenna to another position. 3. Check the connection to the cloud service. State Connection Blinks yellow every 5 s...
  • Page 17: Troubleshooting

    4 Troubleshooting 4 Troubleshooting 4.1 Symptoms and remedies Symptom Remedy The digital input alarm triggers without cause. • When an active digital switch is used, make sure that the unit and the active digital switch have common ground (earth). • Make sure that the input voltage is more than 15 V.
  • Page 18: Technical Reference

    5 Technical Reference 5 Technical Reference 5.1 Dimensions WS008257A Part Dimension 86 mm (3.4 in) 105 mm (4.1 in) 36 mm (1.4 in) 5.2 Environmental requirements Feature Value Operating temperature -30°C to +70°C (-22°F to +158°F) Storage temperature -10°C to +75°C (14°F to +167°F) Operating humidity 95% relative humidity, non-condensing 5.3 Material...
  • Page 19: Terminals

    5 Technical Reference Network Frequency, band 850, 900, 1800, and 1900 5.7 Terminals 1 2 3 1 2 3 1 2 3 4 5 6 7 8 Connector Name Terminal Description number number Digital input Digital input Active = 24VDC Inactive = 0VDC or not connected Ground (earth) Analog input...
  • Page 20 For more information on how Xylem can help you, go to www.xylem.com Xylem Water Solutions Global Visit our Web site for the latest...