Flow direction indicator

The LCD displays a flow direction indicator at the lower right. A circle containing a "+"
represents a positive flow while a circle containing a "-" represents a negative flow. If no
circle is present, there is no flow or the flow is so minimal it cannot be detected.

Notification view

The Notification view provides more information about any alarms or events that have
been triggered. This is in addition to the bell and flag icons that display on the LCD.
The first two digits on the left in Notification view are AL, which is the indication that you
are in Notification view. The remaining six digits in that line display the alphanumeric
symbol for the alarm or event, with the most recent being the first one on the right and
moving from right to left. Only six alarms or events can display at the same time. Active
events flash.
For more information on alarms and events, see

Smart Mode and Normal Mode

The OMNI+ can be configured in either Smart Mode or Normal Mode.
In Smart Mode, the register read consists of the AMI/AMR reading digits, the customer
ID, and any alarms present with a timestamp. In Normal Mode, the register read only
has the customer ID and the AMI/AMR reading digits. In Normal Mode alarm
information is still available, but only by retrieving a data log; no alarm information is
passed on to an AMI system.
The third LCD digit from the left indicates the register is configured for Normal reading
mode. A lowercase 'n' displays in the third digit from the left when the meter is
configured for Normal reading mode.
If the device is reporting in any other mode other than Normal mode, such as Smart
Meter mode, the third value is blank.