Two-Way Smartpoint Modules; Activate Two-Way Smartpoint Modules - Xylem OMNI sensus C2 User Manual

Table of Contents

Advertisement

6 Two-way SmartPoint modules

This section describes how to use FieldLogic Tools to activate, deactivate, configure,
and view the parameter settings of a two-way SmartPoint module. It also covers how to
enable an unused port.

Activate two-way SmartPoint modules

Note: If the configuration's GPS source is set to Required for all SmartPoints and
the field device has no GPS fix, the SmartPoint will not be activated. See the
FieldLogic Tools Installation Guide for more details.
1. Power on the field device.
2. Power on the CommandLink (CL) and place it in the proper position in relation to
the SmartPoint module. This position depends on whether you are activating a Pit
unit or Non-Pit unit.
Note: Make sure the white square on the CL is lined up on the register side.
3. For Non-Pit Units (510M): Position the CL's antenna area on the left side of the unit
with the battery door of the CL facing away from the SmartPoint module. Then
secure it with the strap, if possible. If the left side of the unit is obstructed, place the
CL as close to the mark on the adapter housing as possible.
Note: The label of the CommandLink should be touching the unit, and the
CommandLink's power button should be visible while viewing the front of the
unit.
4. For Pit Units (520M): Remove and flip over the pit lid so that the unit is upside-down.
Position the CommandLink's Antenna area on the unit's bottom side. Then secure it
with the strap, if possible.
Note: The battery door of the CommandLink should be facing away from the
unit, and the label of the CommandLink should be touching the bottom of
the unit.
6 Two-way SmartPoint modules | 24

Advertisement

Table of Contents
loading

This manual is also suitable for:

Omni sensus f2Omni sensus r2Omni sensus t2

Table of Contents