2 LCD display

The LCD is the visual reporting mechanism for the meter.
The display contains dedicated display areas for information and icons. Multiple views
are available; use the lid to toggle through the various views. The first view available
when opening the lid is the Segment Test view. This is visible for one second and shows
all of the various display areas before flashing off.
The second view is the Totalizer view, which is the main visible view when the lid is
open. If the lid is left open, the display stays on in Totalizer view. If the lid remains open
for one hour in any view other than the Totalizer view, the display returns to the Totalizer
view. If the lid is closed and then reopened within 30 seconds, the display switches to
the next view in the sequence. If the lid is closed for more than 30 seconds, the view
resets and starts with the Segment Test view. The lid must be closed for two seconds to
advance to the next view.
The OMNI+ supports the following views:

Segment Test view

Totalizer view
Notification view (for alarms)
Flow Rate view
Totalizer Test view
Segment Test view
The Segment Test view displays all icons to ensure they are all still operational. This view
helps testers and operators troubleshoot the display to ensure parts of the display
correctly display as expected and stop displaying as expected.
The Segment Test view is always available regardless of the device type or operating
mode the device may support.
The segment test only flashes segments that have a use on the device. For example, if
the device does not support meter size, the meter size icons do not display during the
segment test for that device.
The OMNI+ does not use the meter size or radio icons. The segment test displays as
follows:
2 LCD display | 6