Enable/Disable Code 39 Full Ascii; Set Length Range For Code 39 - Newland BS80 User Manual

Hide thumbs Also See for BS80:
Table of Contents

Advertisement

Enable/Disable Code 39 Full ASCII

The scanner can be configured to identify all ASCII characters by scanning the appropriate barcode
below.
Disable Code 39 Full ASCII

Set Length Range for Code 39

The scanner can be configured to only decode Code 39 barcodes with lengths that fall between (inclusive)
the minimum and maximum lengths. To accomplish it, you need to set the minimum and maximum
lengths.
If minimum length is set to be greater than maximum length, the scanner only decodes Code 39 barcodes
with either the minimum or maximum length. If minimum length is same as maximum length, only Code
39 barcodes with that length are to be decoded.
Set the Minimum Length
Example: Set the scanner to decode Code 39 barcodes containing between 8 and 12 characters
1.
Scan the Set the Minimum Length barcode.
Scan the numeric barcode "8" from the "Digit Barcodes (1D Scanner)" section in Appendix.
2.
Scan the Save barcode from the "Save/Cancel Barcodes (1D Scanner)" section in Appendix.
3.
4.
Scan the Set the Maximum Length barcode.
Scan the numeric barcodes "1" and "2" from the "Digit Barcodes (1D Scanner)" section in Appendix.
5.
Scan the Save barcode from the "Save/Cancel Barcodes (1D Scanner)" section in Appendix.
6.
75
Enable Code 39 Full ASCII
Set the Maximum Length
(default)

Hide quick links: