Check Digit Verification

Disable
Transmit Check Digit After Verification

Set Length Range for Interleaved 2 of 5

The scanner can be configured to only decode Interleaved 2 of 5 barcodes with lengths that fall between
(inclusive) the minimum and maximum lengths. To accomplish it, you need to set the minimum and
maximum lengths.
If minimum length is set to be greater than maximum length, the scanner only decodes Interleaved 2 of 5
barcodes with either the minimum or maximum length. If minimum length is same as maximum length,
only Interleaved 2 of 5 barcodes with that length are to be decoded.
Set the Minimum Length
Example: Set the scanner to decode Interleaved 2 of 5 barcodes containing between 8 and 12
characters
1.
Scan the Set the Minimum Length barcode.
Scan the numeric barcode "8" from the "Digit Barcodes (1D Scanner)" section in Appendix.
2.
Scan the Save barcode from the "Save/Cancel Barcodes (1D Scanner)" section in Appendix.
3.
4.
Scan the Set the Maximum Length barcode.
Scan the numeric barcodes "1" and "2" from the "Digit Barcodes (1D Scanner)" section in Appendix.
5.
Scan the Save barcode from the "Save/Cancel Barcodes (1D Scanner)" section in Appendix.
6.
Do Not Transmit Check Digit After Verification (default)
Set the Maximum Length
58