PROBLEM
CAUSE
The stove is without
power supply
Burned protection
fuse in the electric
socket
The control display
Faulty control
does not switch on
display
Faulty flat cable
Faulty electronic
board
Empty hopper
Open fire door or
open pellet door
Clogged stove
Pellets do not reach
the combustion
chamber
Auger blocked by a
foreign object (for
example nails)
The auger geared
motor is out of order Replace the geared motor.
Check if on the
display there is an
"ACTIVE ALARM"
36
RIVER IDROTECH 18 - 24 - 24H2O
SOLUTION
Check if the plug is connected.
Replace the protection fuses in the electric socket (3.15A-250V).
Replace the control display.
Replace the flat cable.
Replace the mother board.
Full the hopper.
Close fire door and pellet door and check that there are no pellet
grains at the gasket level.
Fume chamber cleaning
Clean the auger.
Have the stove checked.