Cadel RIVER IDROTECH 18 Installer Manual page 27

Pellet thermostove
Table of Contents

Advertisement

LEGEND
Disconnect any three-way valve and stove internal flow switch, if equipped with a DHW kit.
7.13 CONFIGURATION 5
7.13.1 System with: pellet stove connected directly to a storage tank for maintaining the temperature set and
controlled through a thermostat connected to it
All activities relating to electrical connections in the electronic board must be carried out by
authorised personnel.
Adjustable setting
SETTING
ROOM TEMP.
EXTERNAL THERMOSTAT
SEASON
AUTO ECO
BOILER WATER TEMP.
SETTING
Parameters to set
Hydraulic diagram
27
RIVER IDROTECH 18 - 24 - 24H2O
Fig. 43
1
Stove
2
Cold H2O manifold
3
Hot H2O manifold
4
3-way valve
5
Electronic board
6
Zone valve
7
Radiator
8
Storage tank
9
Thermostat
10
Release pump
11
Room thermostat
12
Expansion vessel
A
Room thermostat independent from the stove (to be connected to the zone valves, if necessary)
B
Thermostat to be connected directly to the electronic board (see electrical system)
VALUES
Cannot be activated
ON (connect storage tank probe)
WINTER (summer cannot be activated)
ON (it may not be disabled)
80 °C (to be adjusted according to the temperature chosen for
the storage tank)
SETTING
CONFIGURATION
VALUES
5

Advertisement

Table of Contents
loading

This manual is also suitable for:

River idrotech 24River idrotech 24h2 o