19 ALARM

The alarms are divided into the following categories:
1. Signal only alarms (only a signal on the display, alarm relay)
2. Circuit alarms (they deactivate only the relative circuit, signal on the display, alarm relay)
3. Serious alarms (they deactivate all the system circuits, signal on the display, alarm relay)
4. Gas alarms (alarms related to the management of flammable gas)
The alarms must be considered as being manually reset, except for those specified otherwise.

19.1 SIGNAL ONLY ALARMS

Alarm
Pump maintenance
Compressor maintenance
Anti-freeze
Envelope (On/Off compressors)
Excessive entries in memory T
T Memory Error

19.2 CIRCUIT ALARMS

Alarm
High pressure
Low pressure
Low pressure LOW
Compressor thermal
Oil differential
Condenser pump thermal
Evaporator antifreeze
Condenser antifreeze
Discharge refrigerant temperature
Pressure differentials
Probes faulty
Evaporator gas antifreeze
Increment/decrement relay
A.T. fault
Anti-freeze
Unit offline
Refrigerant drain circuit
Electronic valve alarms
Inverter alarms

19.3 SERIOUS ALARMS

Alarm
Phase monitor
Evaporator pump thermal
Water inlet probe failure
Water flow failure
Low pressure
Condenser High Pressure

19.4 GAS ALARMS

Alarm
High pressure
Low pressure
Gas Leakage
Source
Count
Count
Digital input
Transducers
System
System
Source
Pressure switch
Transducer
Transducer
Transducer
Digital input
Digital input
Digital input
Probe
Probe
Probe
Transducers
Probes
Probe
A.T.
A.T.
Probe
Valve driver
Inverter
 
Source
Digital input
Digital input
Probe
Flow switch
Settable bypass from pump start and acquisition delay
Pressure switch
Transducer
Settable threshold and duration of permanence above the threshold
Source
Pressure switch
Pressure switch
Leak detector
Features
Settable threshold
Settable threshold
 
Features
Settable threshold and differential
Delayed with respect to compressor start
Bypassed during and after the pumpdown cycle
Settable alarm bypass time from compressor start
Settable alarm threshold and differential
Enabled from the menu
Settable threshold and differential
Delayed at acquisition
Settable acquisition delay time
Settable threshold and differential
Settable threshold and differential
Settable threshold and differential
Settable threshold and delay from start
Settable threshold and differential
Settable threshold and differential
Features
Delayed with respect to compressor start
Bypassed during and after the pumpdown cycle
Settable alarm bypass time from compressor start