Download Print this page
AERMEC PXA I Use And Installation  Manual

AERMEC PXA I Use And Installation Manual

Electronic control panel for fan coils

Advertisement

Quick Links

PXA I
PANNELLO COMANDI ELETTRONICO PER
VENTILCONVETTORI
INSTALLAZIONE A BORDO DEL VENTILCONVETTORE
ELECTRONIC CONTROL PANEL FOR FAN COILS
INSTALLATION ON THE FAN COIL
PANNEAU DE COMMANDE ELECTRONIQUE POUR
VENTILO-CONVECTEURS
INSTALLATION EMBARQUÉE SUR LE VENTILO-CONVECTEUR
ELEKTRONISCHE BEDIENTAFEL FÜR
GEBLÄSEKONVEKTOREN
INSTALLATION AM GEBLÄSEKONVEKTOR
TABLERO DE MANDOS ELECTRÓNICO PARA FAN COILS
INASTALACIÓN A BORDO DEL FAN COIL
ISO 9001 - Cert. n° 0128/4
M A N UA L E D ' U S O E I N S TA L L A Z I O N E
U S E A N D
I N S TA L L AT I O N
MANUEL D'UTILISATION ET D'INSTALLATION
BEDIENUNGS- UND INSTALLATIONSANLEITUNG
M A N UA L D E U S O E I N S TA L A C I Ó N
M A N UA L
APXAIUJ
0609
50738.50_01

Advertisement

loading

Summary of Contents for AERMEC PXA I

  • Page 1 MANUEL D'UTILISATION ET D'INSTALLATION BEDIENUNGS- UND INSTALLATIONSANLEITUNG M A N UA L D E U S O E I N S TA L A C I Ó N PXA I PANNELLO COMANDI ELETTRONICO PER VENTILCONVETTORI INSTALLAZIONE A BORDO DEL VENTILCONVETTORE...
  • Page 2: Operation

    “PXA E” is easy to use and will be with you for many years to come. The PXA I regulation thermostats are control panels for fan coils for The panel comprises: installation on the machine. – (A) on-off selector switch and ventilation speed;...
  • Page 3: Frost Protection

    Controls To turn on the FCX U - FCS U - Omnia HL S / SM - Omnia UL S / MS fan coils first open the fins. Speed selector (A) Power down command. Standstill status might be of two types, Frost Protection or All Off (contact the installation engineer to find out the set configuration).
  • Page 4: Dip Switch Configuration

    DIP-SWITCH CONFIGURATION SETTINGS To be done in the installation phase, only by expert personnel. Sw1 Dip 5 (Default OFF ) Heating mode enabling temperature: Some functions are not compatible with each other and, for this reason, limits to Dip-Switch configurations have been set. - Reduced, set (ON).
  • Page 5: Installation

    INSTALLATION WARNING: check that the power supply is disconnected before AUTOTEST FOR INSTALLATION performing operations on the unit. It is possible to activate an Autotest mode that makes it possible to WARNING: electrical wiring, installation of the fan coils and check the turning on of all the loads.
  • Page 6 SCHEMI ELETTRICI • WIRING DIAGRAMS • SCHEMAS ELECTRIQUES • SCHALTPLANE • ESQUEMAS ELÉCTRICOS LEGENDA • READING KEY • LEGENDE • LEGENDE • LEYENDA = Contatto esterno = Scheda di controllo = Valvola a tre vie External control Electronic control board Three way valves Contact extérieur Platine de contrôle...
  • Page 7 AERMEC S.p.A. si riserva la facoltà di apportare in qualsiasi momento tutte le modifiche ritenute necessarie per il miglioramento del prodotto. Les données mentionnées dans ce manuel ne constituent aucun engagement de notre part. Aermec S.p.A. se réserve le droit de modifier à tous moments les données considérées nécessaires à...