Silicon Anomaly List
21.
17000067 - ADCC Frame Interrupt Status Register Must Be Cleared Between Frames:
DESCRIPTION:
When the ADCC_NUMFRAMx register is zero, the ADCC_FISTAT.FINTx bit is set after all the events related to a frame have completed.
When the ADCC_NUMFRAMx register is non-zero, the ADCC_FISTAT.LFINTx bit is also set after all the events related to all the frames
(ADCC_NUMFRAMx + 1) have completed.
When the ADCC_FISTATx status bits are set, they must be cleared before the next ADCC timer trigger. Else, a trigger overrun error
interrupt (ADCC_ERR) is generated, which stops subsequent sampling, leading to data loss. An event interrupt handler
(ADCC_TMR_EVT) clears the ADCC_FISTATx status bits. This leads to a long sequence of actions (allowing the sampling to complete,
DMA to drain, and handler to be invoked), which may prevent three to five ADC conversion slots in the frame from being used, especially
at higher conversion rates.
WORKAROUND:
1. Use the ADCC_TMRx_EVT trigger master source to trigger a memory DMA transfer that writes to the ADCC system MMR space to
clear the ADCC_FISTAT.FINTx bits. This removes the core from processing the event and automates hardware handling for it.
2. Periodically update the ADCC_NUMFRAMx register to prevent the ADCC_FISTAT.LFINTx bit from getting set. The
ADCC_NUMFRCNT register increments until it reaches the value in the ADCC_NUMFRAMx register, upon which the
ADCC_FISTAT.LFINTx bit is set. Read the ADCC_NUMFRCNT register periodically, and update the ADCC_NUMFRAMx register to a
value that is less than the value read. For example, perform this check and adjustment in the ADCC timer event handler triggered by
assertion of the ADCC_FISTAT.FINTx bit. When the ADCC_NUMFRAMx register is non-zero, the delay incurred to clear the
ADCC_FISTAT.FINTx bit will not cause an overflow error.
APPLIES TO REVISION(S):
0.0
22.
17000075 - Primary ADC Conversions May Fail with Higher Delays Between Subsequent Conversions:
DESCRIPTION:
At room temperature, primary ADC (ADC1 and ADC2) conversion fails when the delay between the subsequent conversions is greater
than 2.8 ms.
This issue can occur with single-channel conversions or simultaneous conversions. In the case of simultaneous sampling conversions, only
the first conversion fails.
WORKAROUND:
The following workarounds can be used:
1. Place an additional NOP between the conversions.
2. Set the delay between the conversions to less than 2.8 ms on the primary ADCs.
APPLIES TO REVISION(S):
0.0
23.
17000076 - First Conversion of ADC0 Fails after AFE Registers Are Accessed:
DESCRIPTION:
When a read/write operation is performed on the AFE_STATUSREG0, AFE_STATUSREG1, or AFE_USERCFG registers, the first
conversion on ADC0 fails. For example, the AFE Initialization after power-on-reset is done via the ADC0 interface (one time initialization). If
ADC0 is used in the application, the first conversion fails. This issue also occurs when FOCP status reading or DAC selection is performed,
followed by ADC0 conversion.
WORKAROUND:
Discard the first sample or perform a dummy access on ADC0.
APPLIES TO REVISION(S):
0.0
ADSP-CM411F/412F/413F/416F/417F/418F/419F
NR004483C | Page 11 of 12 | July 2017