Xantrex XPower 400 Owner's Manual page 64

Hide thumbs Also See for XPower 400:
Table of Contents

Advertisement

Troubleshooting
Table 5-1 Troubleshooting reference
Problem
The engine
being jump-
started will not
start.
The battery
clamps of the
jump-start
cables measure
zero volts.
The light does
not turn on.
5-6
Get user manuals:
See SafeManuals.com
Possible Cause
XPower Powerpack
battery is not fully
charged.
The engine condition
is poor.
External fuse (250 A)
is blown.
The engine start
capacity exceeds the
XPower Powerpack
jump-start capability.
External fuse (250 A)
is blown.
Light bulb has burnt
out.
Solution
Recharge the
XPower Powerpack
battery.
Have the engine serviced.
Replace 250 A, 32 V fuse with same
type and ratings.
Replace 250 A, 32 V fuse with same
type and ratings.
Remove lens cover and replace bulb
with one of the same type and rating.
975-0057-01-01