Troubleshooting
Table 5-1 Troubleshooting reference
Problem
Measured AC
output voltage
is too low.
Charging
Status light is
Off when AC
Charger is
connected
Green
Charging
Status light is
flashing
(indicating
recharging)
and Battery
Charge (%)
does not turn
on.
5-4
Get user manuals:
See SafeManuals.com
Possible Cause
Use of an
average-reading, AC
voltmeter to read
output voltage.
Battery is almost fully
discharged.
No AC power at the
AC wall outlet.
AC Charger is faulty.
Battery Charge (%)
reading on digital
display is only
accurate when the
XPower Powerpack
has been disconnected
from all appliances
and all charging
sources for fifteen
minutes.
Solution
The modified sinewave (MSW)
output of the
XPower Powerpack
requires a true RMS reading meter,
such as the Fluke 87 series, for
accurate measurement.
Press Display Function button to
verify battery status and recharge the
XPower Powerpack
as necessary.
"Battery Charge %" reading on the
digital display is only accurate when
the
XPower Powerpack
disconnected from all appliances and
all charging sources for fifteen
minutes.
Ensure power is available at the AC
wall outlet.
Replace the AC Charger.
Unplug the charging sources and any
appliances and let the
XPower
Powerpack
rest for 15 minutes to
obtain an accurate reading.
975-0057-01-01