Configuring with the WBM
7.3 The menu items of the WBM
Table 7- 8
Parameters in the "Reader parameters" parameter group II (Freeport)
Parameter
Interface
Parity
Data bits
Stop bits
80
Parameter value
RS422
RS232
None
Odd
Even
Fixed value 1
Fixed value 0
7
8
1
2
Default value
Description
RS232 / RS422
Selection of the interface type that the
connected hardware (reader / optical readers)
uses.
The default value depends on the interface
used:
None
Parity selection
A sequence of data bits can be expanded by a
parity bit. With its value "0" or "1", the parity bit
is added to the sum of all bits (data bits and
parity bits) to form a defined status. This
increases data reliability.
Note: The values "Fixed value 0" and "Fixed
value 1" are not supported by Linux systems. In
this case, the value "None" is used
automatically.
8
Selection of the number of bits to which a
character is mapped.
1
Selection of the number of stop bits that
indicate the end of a character.
The stop bits are appended to every transferred
character during transmission.
SIMATIC RF185C, RF186C, RF188C, RF186CI, RF188CI
Operating Instructions, 03/2022, C79000-G8976-C512-04
None:
Data is sent without a parity bit.
Odd:
The parity bit is set so that the sum of the
data bits (including the parity bit) is odd
when the signal state is "1".
Even:
The parity bit is set so that the sum of the
data bits (including the parity bit) is even
when the signal state is "1".
Fixed value 1:
The parity bit is set permanently to the value
"1".
Fixed value 0:
The parity bit is set permanently to the value
"0".