SIMATIC RF185C, RF186C, RF188C, RF186CI, RF188CI
Operating Instructions, 03/2022, C79000-G8976-C512-04
AutoId
text
DEVICE_FAULT
--
--
--
--
--
--
--
--
Error description
Antenna errors
The antenna or the antenna cable is defective.
Error in the connection to the reader; the reader is not
answering (in PROFIBUS operation).
The cable between the communication module and
reader is wired incorrectly or there is a cable break
The 24 V supply voltage is not connected or is turned off
or has failed briefly
Automatic fuse on the communication module has
blown
Hardware defective
Another reader is in the vicinity and is active
There is a reflecting metal surface in the vicinity that is
disrupting the antenna field
Execute "init_run" after correcting the error
The selected antenna is not enabled.
The command is not permitted in this status or is not supported.
Possible cause:
"INIT" was chained.
Command repetition was started without "Presence mode".
No or bad configuration data/parameters were transferred.
Possible cause:
You are accessing a read point that is not configured.
A parameter is missing.
The parameter has an invalid format.
The parameter type is invalid.
Unknown parameter.
The command or the frame has an invalid format.
Service and maintenance
9.2 Error messages
139