Configuring with the WBM
7.3 The menu items of the WBM
Parameter
Diagnostics
messages
Read point name
Transmission
speed
User mode
Location
The parameter values of the basic parameters can be preset automatically using the
"Autoconfiguration" button. By pressing the button, the communication module
automatically identifies the device connected to the interface and sets the appropriate
parameter values.
Using the "Update firmware" link, you jump to the "System - Reader firmware" menu item in
which you can update firmware for the connected reader.
76
Parameter value
None
Hard errors
Hard/soft errors
--
19.2 kBd
57.6 kBd
115.2 kBd
921.6 kBd
Ident profile/RFID
standard profile
FB 45
--
Default value
Description
None
Shows which diagnostic messages have been
set in STEP 7 (cf. Section "Parameterization of
the diagnostics (Page 127)"):
--
In the text box, you can assign a name to the
read point(s) (for example, "Incoming goods
gate 5" or "Welding robot 21"). Note that the
name is required for addressing the reader via
OPC UA.
115.2 kBd /
Selection depends on the Ident device/system
921.6 kBd
being used. With this parameter, you set the
data transmission speed between the
communication module and the reader.
Ident profile/RFID
Shows which block has been set in STEP 7:
standard profile
--
Input box to enter information on the location
of the read point.
SIMATIC RF185C, RF186C, RF188C, RF186CI, RF188CI
Operating Instructions, 03/2022, C79000-G8976-C512-04
None:
Apart from standard diagnostics, no other
alarms are generated.
Hard errors:
Critical hardware errors/faults are reported
by the S7 diagnostics.
Hard/soft errors:
Critical hardware errors and errors that occur
during command processing are reported by
the S7 diagnostics. The "Ext_Diag" bit is set.
Ident profile/RFID standard profile:
The program block for the Ident profile/RFID
standard profile is used on the controller.
FB 45:
Single tag mode. FB 45
(PROFIBUS/PROFINET) is used in the
controller.
Only in conjunction with an S7-300
controller.