Auto Noise Cancel; Auto Noise Cancel Procedure - Minelab MANTICORE Instruction Manual

Hide thumbs Also See for MANTICORE:
Table of Contents

Advertisement

Noise Cancel
Detectors can become noisy due to
electrical interference from power lines,
electrical equipment or other detectors
operating nearby� The detector interprets
this interference as inconsistent, erratic
detections or 'noise'�
The Noise Cancel setting allows you to change the noise
cancel channel� This slightly shifts the detector transmit
frequency to be less responsive to sources of noise�
Noise Cancel affects both the audible detection noise level
and pinpointing performance�
The Noise Cancel setting has 19 channels with a range from
−9 to 9� It has a default setting of 0 (zero) for all
Search Modes�
Noise Cancel adjustment is local; only the current Search
Mode is affected by changes to this setting�
Auto is the recommended Noise Cancel method�
Perform a Noise Cancel each time the Frequency
setting or Seach Mode is changed�
You can assign Noise Cancel as a Soft Key Action
— see
page
35�
Noise Cancel
0
Noise Cancel in the Settings Menu�
CONTENTS

AUTO NOISE CANCEL

Auto Noise Cancel automatically scans and listens to every
frequency channel and then selects the one with the
least interference�

Auto Noise Cancel Procedure

1. Hold the Coil stationary and away from metal�
2. Navigate to Noise Cancel:
Settings >
Noise Cancel
3. Press the Right Soft Key (
start the Auto Noise Cancel process�
An animation will appear on the screen and there will be
a series of ascending tones�
Auto Noise Cancel
Hold the coil still and away
from metal
Auto Noise Cancel in progress�
4. After approximately 3 seconds, the selected channel will
be displayed before returning you to the Settings Menu�
NOTE: While Auto Noise Cancel selects the quietest
channel based on several criteria, the selected
channel may still have some audible noise�
Repeat Auto Noise Cancel or try Continuous Auto Noise
Cancel to see if it will further reduce noise�
57
Auto Noise Cancel) to
Auto Noise Cancel
-8
Hold the coil still and away
from metal
Auto Noise Cancel complete�