'_ -\
I'
.,
,,-.
,
'\
,-\
c.
Attaching
the Primarymransfer
Corona
Assembly
Wire
n
Primary Corona Assembly
1)
Remove
the four tension
springs
0,
and detach the grid plate 0.
Figure 4-504
n
Transfer Corona Assembly
2)
Detach
the gut wire from the transfer
corona assembly;
see p. 4-20.
3)
Free about 40 mm from the corona wire
reel (0.06 mm dia.), and form a loop at
its end about 2 mm in diameter.
4)
Cut the twisted end of the corona wire
to about 1 mm or less using a nipper.
5)
Hook the loop of the corona
wire as
shown
in Figure
4-505,
and lead the
wire along the V-groove
of the height
adjusting roll.
Hook the corona wire tension spring on
the corona
wire, and twist the spring
three to four times as shown.
Primary corona assembly
Transfer corona assembly
Figure 4-505
6)
Cut the excess corona wire to about 1
mm or less using a nipper.
7)
Pick the end of the corona wire tension
spring using tweezers,
and hook it on
the corona terminal.