B. Primaryflransfer
Corona
Assembly
1.
Outline
The photosensitive
drum is surrounded
by
the
primary
and
transfer
corona
assemblies.
The
primary
corona
assembly
is
equipped with a grid plate.
2.
Disassembly/Assembly
a.
Primary Corona Assembly
1)
Detach the drum unit.
2)
Disengage
the hook 0, and pull out the
primary
corona
assemblv
@ from the
drum unit.
Figure 4-501
b:
Transfer
Corona
Assembly
Gut Wire
~_
and Static Eliminator
1)
Detach
the transfer
corona
assembly
\
from the copier.
2)
Remove the two screws 0, and detach
the static eliminator, taking care so that
the gut wire will not come off.
Figure 4-502
__ ,7
3)
Detach the static eliminator 0.
Figure 4-503
,/-