1.6

ARM CONTROL

NOTICE
The FLAMEBLAZER is configured for safety control with an ARM SYSTEM. The
FLAMEBLAZER cannot be operated without the safety signal from the control unit of
the ARM SYSTEM: The ARM CONTROLLER. When there's no signal, the internal relief
valve opens. The system depressurises immediately and prevents the FLAMEBLAZER to
produce any high-risk SFX output. As a result, any related hazard/or property
damage is stopped and prevented.
The ARM CONTROLLER is equipped with a key switch to arm/disarm the connected
SFX machine(s), an emergency stop button, and a reset button. The ARM SYSTEM is
wired with EtherCON cables that carry the safety signal from the ARM CONTROLLER.
For more information about the ARM SYSTEM and to learn how to configure a
complete safety system, refer to the ARM SYSTEM Configuration Manual (PART02323).
For more information about the ARM CONTROLLER and to learn how to correctly set
up and use the ARM SYSTEM, refer to the ARM CONTROLLER User and Installation
Manual (PART01882).
1.7

DMX CONTROL

The FLAMEBLAZER is controlled with 1 enable address and 1 operational address:
DMX address
Enable address
Start address
The enable address cannot be the same as the operational address. Operating of
these addresses results in the following:
DMX address
Enable address
Start address
(Effect trigger)
10
MAGICFX FLAMEBLAZER
The FLAMEBLAZER cannot be operated without connection to an
ARM CONTROLLER in an ARM SYSTEM.
Address range
1 - 512
1 - 512
DMX Value (decimal)
0
99
100
154
155
255
0
199
200
255
— User and Installation Manual
®
Control
Device enable/disable
Effect trigger
Result
Device disabled
Device enabled
Device disabled
No output
Output effect
Operation of the DMX addresses
DMX addresses