Magicfx FLAMEBLAZER User And Installation Manual page 13

Hide thumbs Also See for FLAMEBLAZER:
Table of Contents

Advertisement

Menu function
Lock/Unlock
Controller
Reset Errors
DMX Start
Address (1-512)
DMX Enable
Address (1-512)
DMX Footprint
DMX input
(XLR/ARM)
RDM (On/Off)
Pyro Input
Control (On/Off)
Display Dimmer
(On/Off)
Factory Defaults
(Yes/No)
Type
(Alarm/Error)
Serial Number
(DDDDD)
Unique ID
(HHHHHHHHHHHH)
Software Version
Software CRC
Bootloader CRC
Build Date
Uptime
(DDDD:HH:MM:SS)
Effect Time
(DDDD:HH:MM:SS)
Explanation
Holding the Lock button for more than 5 seconds will "lock" the
display functions. Meaning buttons will not respond. This to avoid
accidental change of parameters via display. To unlock, hold
the Unlock button for more than 5 seconds. In case system is
armed display is locked.
In case there is a locking error present, this button will reset the
appliance. If the fault does not persist, the locking error will not
reappear.
Setting the DMX start address.
Setting the DMX Enable Address.
This parameter indicates the DMX footprint, in other words the
amount of sequential channels used by the appliance. This does
not include the enable channel.
Make sure that the DMX/RDM settings on your machine match
your wiring setup. If the DMX signal runs separately over 5-pole
XLR cables, make sure that XLR is selected. If a combined DMX
and ARM signal runs over the ARM data (EtherCON) cables,
make sure that ARM is selected.
Use this function to turn on/off the RDM functionality.
Use this function to toggle between the control modes DMX and
Pyro
Turn display dimmer on or off. If turned on, the display is dimmed
automatically 30 seconds after the last button push.
Restores the appliance factory default settings.
Toggle between the occurred locking error (Alarm) list, and
blocking error (Error) list. Locking errors need intervention by
user, although they are "auto-reset" 3 times before the appliance
remains in error until reset by user. Blocking errors clear when the
triggering fault disappears. 16 locked, and 16 blocked errors are
logged. Top of the list shows the last occurring error.
Appliance serial number as also printed on the appliance label.
UID number as the appliance appears in the RDM device list
after running discovery.
Installed software version.
CRC of the functional software.
CRC of the bootloader software.
Release date of functional software.
Time counter which indicates how long the appliance has been
powered in total.
Time counter which indicates how long the effect has been on in
total.
MAGICFX FLAMEBLAZER
— User and Installation Manual
®
Menu functions
13

Advertisement

Table of Contents
loading

Table of Contents