Overnight Quick Recording Setup

This sets up a recording session which will start at 2am. Three recordings will be made
each 20 seconds long, one hour apart.
Recording start time:
Interval between recordings:
Length or each recording:
Number of recordings:
Check the table at the bottom of this page to see if it is suitable for your test.
1. Press MODIFY to cycle through the menu options until you see "Set recording 2"
2. Press OK to start the recording setup
If the loggers contain any data then it will be downloaded before the new recording is set
up. This ensures that the data in the loggers cannot be lost accidentally by setting up a
new recording. All recordings will be available for download in the SoundSens software.
When the recording setup is complete the screen will show a confirmation message, e.g.
The number of loggers programmed is displayed, and the right side of the screen shows a
map of the positions of the programmed pods ('O' represents a logger present and a '-'
shows a vacant position). If this differs from the actual positions of the loggers below the
most likely explanation is that the windows on top of the pods are dirty or that an object is
on top of the loggers.
Pipe
Up to 6" Metal
8" +Metal
Up to 6" AC
8"+ AC
Up to 4"MDPE?PVC
4" + MDPE/PVC
300+Steel
SoundSens User Guide
Leak Localisation and correlation
2 am
1 hour
20 sec
3
4 LOGGERS
-O—-
PROGRAMMED
-OOO
Short distances
Metre
10 Seconds
500
20 Seconds
400
10 Seconds
100
20 Seconds
80
30 Seconds
50
60 Seconds
50
SoundSens User Guide
©Radcom (Technologies) Ltd
Long distances
Metre
10-20 Seconds
1000
20-30 Seconds
800
20 Seconds
500
30 Seconds
500
60 Seconds
100
120+Seconds
100
20 Seconds
500
Very long
distances
60 Seconds
1000+