FCS Soundsens i User Manual page 15

Table of Contents

Advertisement

Pipe
Up to 6" Metal
8" +Metal
Up to 6" AC
8"+ AC
Up to 4"MDPE?PVC
4" + MDPE/PVC
300+Steel
NOTE : On sites with mixed pipe material always select the longest sample period. So if
you have some 6" and some 8" Metal (less than 500 metre lengths) select 20 seconds.
The recording interval is the gap between the START times of each recording.
e.g. if three recordings of 1 minute each are set to start at 1AM with a recording interval of
1 hour then the start times will be 1am, 2am, 3am. If the recording interval is 15 minutes
then the start times will be 1am, 1:15am and 1:30 am.
Radcom recommends 3 recordings – see explanation below.
The recording interval needs to be set with local knowledge in mind. Think of how long it
takes for a toilet to fill in your local area, and set the recording interval to that time. This
will help reduce the detection of noise which is due to legitimate consumption.
This is also partly the reason why we suggest 3 recordings. If a logger detects a noise
which can be put down to legitimate usage then hopefully on the second or third recording
the usage will have stopped.
SoundSens User Guide
Leak Localisation and correlation
Short distances
Metre
10 Seconds
500
20 Seconds
400
10 Seconds
100
20 Seconds
80
30 Seconds
50
60 Seconds
50
SoundSens User Guide
©Radcom (Technologies) Ltd
Select the sample period.
This is determined by the pipe material and
diameter.
Suggested sample periods for pipe materials
and lengths are shown below.
Long distances
Metre
10-20 Seconds
1000
20-30 Seconds
800
20 Seconds
500
30 Seconds
500
60 Seconds
100
120+Seconds
100
20 Seconds
500
Set the number of recordings
(max 9), and set the recording interval
(between 1 minute and 3 hours)
Some combinations of sample periods and
number of recordings will cause excess
memory usage. This is due to memory size
restrictions in the logger.
Very long
distances
60 Seconds
1000+
Page 15 of 63

Advertisement

Table of Contents
loading

Related Products for FCS Soundsens i

Table of Contents