3.3

Test I-7530A on CAN network (Only for normal mode)

The following procedure will guide you to learning how to
transmit/receive CAN messages to/from other devices/PCs by using the I-
7530A converter. Note that users can only employ this test function for
the system if they are using the default communication parameters for the
RS-232/485/422 as provided above.
1. Set the Init/Normal switch to the Normal position, which is found at the
back of the I-7530A module.
2. Connect the I-7530A's CAN port into the CAN network, which must at
least have one CAN device on the network.
3. Supply the 10~30 volts DC source into the I-7530A module through the
power terminal.
4. The ON LED on the I-7530A module will be turned on. That means the
I-7530A is working in the operation mode.
5. Run the I-7530A Utility software after there is a wire connection as
shown in Section 2.5.
6. Select the "Test" tab and click the "Connect" icon on the tool bar in the
I-7530 Utility to configure the PC COM port and Baud rate, which will be
used to connect to the COM port of the I-7530A.
7. Press the "OK" button. Then the I-7530 Utility will show the test tab in
the window as can be seen in the below figure.
I-7530A RS-232/485/422 to CAN Converter User's Manual (Version 1.2, Sep/2011) ------------- 19