2.5

Init/Normal Dip-switch

On the back of the I-7565 module, there is a dip-switch used for
setting the operation or configuration mode of the module function. In the
normal situation, the user needs to first make a configuration in order to
provide the correct function when the module works in the operation mode.
The following steps show how to use this dip-switch.
(1) Configuration mode: Please first set the dip-switch to the "Init" (Initial)
position. Then the I-7565 will work in the configuration mode after the
power for the module has been turned on. In this case, users can
configure the communication parameters of the I-7565 module by
using the I-7565 Utility tool.
(2) Operation mode: After the configuration, users need to set the dip-
switch to the "Normal" position. Users need to turn the power off then
on again so that they can use the I-7565 in the operation mode. Once
you have completed your configurations and switched to the operation
mode, then messages can pass between the CAN and the USB ports.
This transmission process depends on the configuration parameters
that the users have configured. That is, the I-7565 functions as a
USB/CAN converter.
I-7565 USB/CAN Converter User's Manual (Version 1.0, March/2007)
Figure 7: Dip-switch of I-7565