Polling Commands And Responses - Omron V720 Series Operation Manual

Electromagnetic inductive rfid system, id controller
Hide thumbs Also See for V720 Series:
Table of Contents

Advertisement

Communications Commands and Responses

5-3-5 Polling Commands and Responses

1) Polling Single Auto Read (PR)
Immediately after receiving the Polling Single Auto Read Command, the Controller returns a re-
sponse indicating the acceptance of the command and waits for a Tag to enter the communica-
tions area of the Antenna. Then it reads the data of the entering Tag. The host can inquire of the
Controller the results of communications processing using a subcommand.
  
Command Frame Structure
STX Node No. Command
1
2
Data type
First read page
No. of read pages
  
Response Frame Structure
STX Node No.
1
2
Response code
5-14
Data
First read
code
type
page
"PR"
2
1
2
Specifies whether the read data is represented in ASCII or HEX.
A: ASCII code
H: HEX code
For details, refer to 5-6 Data Type.
Specifies the first page of the Tag containing data to be read in HEX.
Setting range: 00h to 0Ah, FFh
(FFh can be specified only when using Philips' block 4 as user memory. For details,
refer to 2-5 Tag Memory Map.)
Specifies the number of pages to which data is written in HEX.
Setting range: 01h to 0Ch
Retry
Command
Response
flag
code
code
"PR"
"74"
1
2
2
74: Command received.
For other response codes, refer to 5-10 Response Code List.
Note: Philips' block 4 can be used as user memory with Controller software ver-
sions 1.5 or later. The software version can be read with the Version Com-
mand (VS).
No. of read
ETX BCC
pages
2
1
1
ETX BCC
1
1
Section 5-3

Advertisement

Table of Contents
loading

This manual is also suitable for:

V720-cd d seriesV720-cd1dV720-cd2d

Table of Contents