Omron V720 Series Operation Manual page 64

Electromagnetic inductive rfid system, id controller
Hide thumbs Also See for V720 Series:
Table of Contents

Advertisement

Communications Commands and Responses
2) Write (WT)
Command for the use of writing data to an ID Tag.
Read verification processing is performed for this command and so it is not necessary to per-
form it again.
Command Frame Structure
STX Node No. Command
1
2
Communications
Data type
First write page
No. of write pages
Write data
Response Frame Structure
STX Node No.
1
2
Response code
5-6
Commu-
Data
code
nications
type
"WT"
2
2
Specifies a communications method.
ST: Single Trigger
SA: Single Auto
SR: Single Repeat
For details, refer to 5-5 Communications Methods.
Specifies whether the write data is represented in ASCII or HEX.
A: ASCII code
H: HEX code
For details, refer to 5-6 Data Type.
Specifies the first page of the Tag to which data is written in HEX.
Setting range: 00h to 0Ah, FFh
(FFh can be specified only when using Philips' block 4 as user memory. For details,
refer to 2-5 Tag Memory Map.)
Specifies the number of pages to which data is written in HEX.
Setting range: 01h to 0Ch
Indicates data to be written to the Tag.
The number of characters of the data is as follows:
ASCII code: No. of write pages x 4
HEX code: No. of write pages x 8
Retry
Command
Response
flag
code
code
"WT"
"00"
1
2
2
00: Normal completion
For other response codes, refer to 5-10 Response Code List.
Fixed
First write
page
"0"
1
1
2
ETX BCC
1
1
No. of
Write
write
data
pages
2
Specified number
Section 5-3
ETX BCC
1
1

Advertisement

Table of Contents
loading

This manual is also suitable for:

V720-cd d seriesV720-cd1dV720-cd2d

Table of Contents