11.2 SRS battery system
NOTE
Observe procedure.
The maintenance intervals/cleaning of the storage system may only be carried
out after the system is shut down.
NOTE
Observe the aids.
Compressed air and dry cleaning cloths must be used for any cleaning work
that is required.
11.2.1

Replacing the backup battery

A lithium CR2032 button cell is built into the SRC4310. A maintenance interval of three years is
recommended for the button cell. The procedure described in the following for maintenance is to be
observed under all circumstances.
NOTE
Adjusting the time
Replacing the button cell causes the set time to be lost. The time must then be
reset via the web interface.
F
42: R
IGURE
EPLACING THE
Page 66 of 72
SRC4310
BACKUP
- 1
BATTERY
Remove the battery holder with
1
the aid of a screw driver
through the opening via the slot
in the front (marked in blue in
the drawing).
GSS0608