Get Record/Zone 2 Status - Lexicon DC-2 Protocol Manual

Serial communications protocol
Table of Contents

Advertisement

Lexicon, Inc.
DC-2/MC-1 Serial Communications Protocol
Data Type:
Maximum Value:
Packet.
Current Input Sample Rate
Data Type:
Current Input Format:
Data Type:
Mute Active:
Data Type:
TRUE:
FALSE:
Effect Bypass Active:
Data Type:
TRUE:
FALSE:
Left/Right Balance:
Data Type:
Maximum Value:
Conversion:
Front/Back Balance:
Data Type:
Maximum Value:
Conversion:
Video Synch:
Data Type:
TRUE:
FALSE:

7.3.6 Get Record/Zone 2 Status

Request to DC-2/MC-1 for current Record/Zone2 Status. DC-2/MC-1 will respond with "Record/Zone2
Status Packet".
7.3.6.1 Command Packet Description
Unsigned 8 bit integer.
Set by "Total Number of Effects" in the "Unit Configuration"
Unsigned 8 bit integer.
SAMPLE RATE
RATE_UNKNOWN
RATE_44
RATE_48
RATE_88
RATE_96
Unsigned 8 bit integer.
DATA STREAM TYPE
INSTREAM_UNKNOWN
INSTREAM_AC3
INSTREAM_PCM
INSTREAM_ANALOG
INSTREAM_DTS
INSTREAM_AC3_20
INSTREAM_AC3_51
Boolean.
System Mute is Active
System is unmuted.
Boolean.
Effect Bypass is Active
Effect Bypass is not Active.
Unsigned 8 bit integer.
32
0 = Left
32 = Right
Unsigned 8 bit integer.
32
0 = Front
32 = Back
Boolean.
DC-2/MC-1 has detected Video Synch for current video input
DC-2/MC-1 can not detect Video Synch for the current video input
Printed on: 10/19/00
0
1
2
3
4
0
1
2
3
4
5
6
15 of 44