Download Print this page

Figure 1-8: Rs232-Ieee488 Converter Serial Cable Configuration - Motorola SC 300 Manual

Bts hardware installation, atp and fru procedure
Hide thumbs Also See for SC 300:

Advertisement

ATP Tools and Materials
1
Figure 1-8: RS232–IEEE488 Converter Serial Cable Configuration
1-18
– continued
9–pin D (female)
GND 5
RX 3
TX 2
RTS 7
ON BOTH CONNECTORS SHORT
CTS 8
PINS 7 AND 8;
SHORT PINS 1, 4 AND 6
RSD/DCD 1
DTR 4
DSR 6
Communications Test Set w/JCDMA PCMCIA Card
This procedure requires one of the following test sets:
Motorola CyberTest
Advantest R3465 and HP 437B or Gigatronics 8541C Power Meter
Hewlett–Packard HP 8935
Hewlett–Packard HP8921 (w/CDMA and PCS interface for 1.7/1.9
GHz) and HP 437B or Gigatronics Power Meter.
RF power meter (average and code domain)
RF signal generator (capable of CDMA modulation)
Spectrum Analyzer
CDMA code domain analyzer
GPIB cables
Two Hewlett Packard 10833A or equivalent; 1 or 2 meters long used to
interconnect test equipment and LMF terminal.
Power meter
This procedure requires one of the following power meters:
Gigatronics Model 8541C with 80601A power sensor capable of
measuring from –70 dBm to +23 dBm; supported by the LMF to
perform BTS Total Power measurement.
SC 300 BTS Hardware Installation, ATP and FRU Procedures
9–pin D (female)
5 GND
2 TX
3 RX
7 RTS
8 CTS
1 RSD/DCD
4 DTR
6 DSR
NOTE
As of the writing of this manual, the Advantest CDMA
communications test set is the ONLY CDMA analyzer
approved by Motorola for automated BTS testing.
PRELIMINARY
DEC 2000

Advertisement

loading