Download Print this page

Procedure To Install Antenna Cabling For One Antenna; Procedure To Install Antenna Cabling For Multi-Unit Configurations - Motorola SC 300 Manual

Bts hardware installation, atp and fru procedure
Hide thumbs Also See for SC 300:

Advertisement

Antenna Cabling for Sites Equipped With Customer–Supplied Site I/O
Interface
– continued
Procedure to Install Antenna
Cabling for One Antenna
Procedure to Install Antenna
Cabling for Multi–Unit
Configurations
4
Figure 4-13: Antenna Cabling for Three Microcells
MICROCELL 3
KEY
B/1(ANTENNA)
NAME
NUMBER
OF CABLES
LABEL
4-22
*
Route the antenna cable between the unit and the customer–supplied
lightning arrestor. If a lighting arrestor is not required, route the cabling
directly to the antenna. Refer to Figure 4-12 and Table 4-23.
If your site has more than one Microcell or Picocell unit, refer to
Figure 4-13 or Figure 4-14 for site cabling information. Route the
antenna cables between the units and the customer–supplied lightning
arrestors. If lighting arrestors are not required, route the cabling directly
to the antennas.
C/1(ANTENNA)
ANT 4
LA
TX/RX
C/1(ANTENNA)
ANT 3
LA
RX
LIGHTNING
LA =
ARRESTOR
SC 300 BTS Hardware Installation, ATP and FRU Procedures
IMPORTANT
You must install lightning arrestors for all outdoor
installations.
C/1(ANTENNA)
MICROCELL 1
C/1(ANTENNA)
MICROCELL 2
PRELIMINARY
ANT 1
LA
TX/RX
ANT 2
LA
TX/RX