Power, Ground, and Battery Cabling for Sites Equipped With
Customer–Supplied Site I/O Interface

Cables Needed

Table 4-14: Cables Needed for Power, Earth Ground, and Battery Connections

Cable
Qty.
Part Number
S
1–4
3087854C02
U
1–4
3087854C04
Y
1–4
Customer
Supplied

AC Input Cable Information

DEC 2000
SC 300 BTS Hardware Installation, ATP and FRU Procedures
– continued
Table 4-14 provides the quantity and description of the cables needed.
AC input cable, 14 AWG, 5 m, is designed for 88–260 VAC power
input.
DC input cable, 14 and 22 AWG, 5 m, is designed for 20 to 40 VDC
power input.
Ground cable, 6 -AWG, insulated copper wire. Requires one ring lug
connectors.
The pinout information for the AC input cable(s) (Cable S) is given in
Figure 4-9 and Table 4-15.

Figure 4-9: AC Input Cable Connector Information

B

Table 4-15: AC Input Cable Information

Connector
A
B
C
Description
A
SOCKET POSITION ON CABLE
CONNECTOR SHOWN
C
Wire Color
Description
Black
Green
White
PRELIMINARY
4
Line
Ground
Neutral
4-17