Table 12. Mui Prg Menu Groups - Emerson AMPGARD RVSS Instruction Booklet

Reduced voltage soft-starter
Table of Contents

Advertisement

AMPGARD RVSS
Reduced Voltage Soft-Starter
User Manual
Figure 50. MUI Program menu.
Table 12 shows the MUI Program menu (PRG) groups and their
topics.
To access any topic, use the MODE/BACK button to navigate to the
56
PRG menu, then use the
the target topic. Click OK to select, then EDIT if you want to change
56
the setting. Use the
contextural buttons to make changes,
then click SAVE to save changes. Use the MODE/BACK button to
navigate back to other topics or menus
Table 12.
MUI PRG menu groups
1. Monitor
Voltage
Current
Power,
System
Temperature
6. Faults and Events
Active fault
Active warning
Fault snapshot
Tripped status bits
Warning status bits
Go here
to set . . .
Pre-start sub-fault code
Fault queue
11. User interface
settings
Brightness
Idle brightness
Contrast
Default measure
parameters
LED brightness
Inactivity timeout
Timeout behavior
Enable cntrl buttons,
Advanced (UI settings)
N
ote:
Shaded topics are viewable, for monitoring. Unshaded topics are used for setup.
contextural buttons to navigate to
.
2. Motor
3. Wiring
configuration
configuration
Service factor
Motor nominal current
Rated voltage
Rated frequency
Watts motor
HP motor
Motor rated efficiency
Rated power factor
Speed motor
7. Protections
8. Real time clock
General
Current
Voltage
Ground fault
12. Security
13. Services
Local pw
Admin pw
USB pw
4. Operation mode
PT ratio primary
Active op mode
CT ratio primary,
Profile 1 selection,
Phase order (user
Profile 2 selection, l
select ABC / ACB)
Loc cntrl source,
Rem cntrl source,
Loc/rem powerup behavior
9. Communications
Date and time
Modbus
RTC status
Ethernet
Time zone
Daylight savings time
RTC pwr loss alarm
14. Setup wizard
Re-pair external
Motor nominal current FLA
modules
Rated voltage
Factory reset
Rated frequency
Soft reset
Loc cntrl source
DSP param reset
Rem cntrl source
Start ramp time
Initial voltage
Current limit
Incomplete sequence time
Transition TH%. service factor,
Phase order (user select ABC / ACB)
Instruction Booklet IB020003EN
Effective January 2021
5. Soft start configuration
Profile 1 settings
Profile 2 settings,
Transition TH%
Run transition dly
Configurable pre-start check
Ramp transition speed
Truck size
Current foldback speed,
Transition type
10. System view
Base control module
User interface
DSP module
Ethernet card
Input power board
EATON www.eaton.com
49