Chapter 3

Setup Menu

3.1 Setup Menu Overview

Use the meter Setup Menu to customize meter settings.
In the Measure Mode, press the "Menu" key to
access the meter Setup Menu.
The first Setup Menu item (View Logs, Data Log) will
be shown. To scroll through the Setup Menu list,
press the  or  key.
a. Press the  key to scroll to the second item.
b. Press the  key to scroll to the last item.
c. The list is cyclical, so continue to press the 
key to scroll from the last item to the first item.
To change a setting within a Setup Menu item,
press the  or  key.
a. For numeric value changes:
i.
Press the  key once to increase the
value by one least significant digit/unit.
ii.
Press the  key once to decrease the
value by one least significant digit/unit.
iii.
Press and hold the  key to quickly
increase the value.
iv.
Press and hold the  key to quickly
decrease the value.
Once a setting is changed, press the "Enter" key to
save the change.
When viewing data logs or calibration logs, press
the "Menu" key to go back to the main Setup Menu
list.
Press the "Measure" key at any time to exit the
Setup Menu and return to the measure mode.
12
Chapter 3 | Setup Menu
Setup Menu Item
Setting Options for
Setup Menu Item
#
Setup Menu Item Description
1
View Logs
2
Log Export Type
3
Export All Logs
Temperature
Calibration
or
4
Manual
Temperature
Input
5
Measure Mode
Nominal Cell
6
Constant
Temperature
7
Compensation
Coefficient
Reference
8
Temperature
9
TDS Factor
10 Read Type
11 Timed Interval
Calibration Due
12
Alarm
13 Set Date Format
14 Set Date Value
15 Set Time Value
16 Audio Mode
17 Sleep Mode
18 Clear Data
19 Factory Reset
View up to 500 data log points
and active conductivity, salinity,
TDS and temperature
calibrations
Set the export type as computer
or printer or turn export off
Send all saved data logs and
calibration logs to the selected
export device
When conductivity electrode with
built-in ATC sensor is
connected, use the Temp.
Calibration menu to perform a
temperature offset calibration
When conductivity electrode
without ATC sensor is
connected, use the Manual
Temp. Input menu to enter the
sample temperature value
Set the main measure mode to
conductivity, salinity or TDS
Set the nominal cell constant for
the conductivity electrode in use
Set temperature compensation
off or enter the value of the linear
coefficient
Set the reference temperature
for temperature compensation
Enter the TDS factor value
Set the read type to define how
measurements are performed
and when measurements are
saved and exported
When Timed is set as the Read
Type, set the time interval to be
used to automatically save and
export measurements
Set the calibration due alarm
interval; an alarm is triggered if a
calibration is not performed
within the specified time interval
Set the date format as month-
day-year (MM.DD.YYYY) or day-
month-year (DD.MM.YYYY)
Set the day, month and year
Set the time in AM/PM hour
format
Set the audible beep on or off
Set the sleep mode on or off
Erase all data logs or erase all
calibration logs
Erase all data logs, calibration
logs and settings and return the
meter to its factory default state.