Speci cations
Conductivity
Range
0.00 to 20.00 mS
10 µS below 2.00 mS,
Resolution
0.10 mS above 2.00 mS
Relative Accuracy
±2 % full scale ± 1 LSD
TDS
Range
0.00 to 20.00 ppt
10 ppm below 2.00 ppt,
Resolution
0.10 ppt above 2.00 ppt
Relative Accuracy
±2 % full scale ± 1 LSD
Salinity
Range
0.0 to 10.0 ppt
Resolution
0.10 ppt
Relative Accuracy
±2 % full scale ± 1 LSD
Temperature
Range
0 to 50.0 ºC / 32.0 to 122.0 ºF
Resolution
0.1 ºC / 0.1 ºF
Relative Accuracy
±0.5 ºC / ±0.9 ºF + 1 LSD
Automatic
Temperature
Yes
Compensation
General
Includes (4) batteries
Power
(A76 or LR44 equivalent)
Auto-O
8.5 mins after last key press
Operating Temp.
5 to 45 ºC
Ingress Protection
IP67 rating ; waterproof
Dimensions (LxWxH)
17 x 4.5 x 3 cm
Applications
• Water & Wastewater Treatment • Environmental
Monitoring • Education • Hydroponics • Agriculture
• Aquaculture & Aquariums • Pools & Spas • Food &
Beverage Manufacturing • Cooling Towers • Electroplating
• Printing • Photo-Development and more!
1 Year Warranty
Made in Singapore
l
Please refer to inside for operating instructions
This device complies with part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) This device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may cause undesired operation.
IS-EXPERTCTS-E 1016 RevA
Thermo Scienti c
Eutech
Expert CTS
Easy-to-read
4 digit LCD display
Transparent cap with
a wide, stable base
• Large 4 digit
• Simultaneous display of
• Battery life, ready and
Lanyard provision
• Automatic temperature
• Multi language
For use in
environmental
monitoring and more
double line display
conductivity/TDS/salinity
and temperature
calibration indicators
compensation
operational instructions

Advertisement

loading
Need help?

Need help?

Do you have a question about the Eutech Expert CTS and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Thermo Scientific Eutech Expert CTS

  • Page 1 Thermo Scienti c ™ i t n c i f ™ Eutech ™ Eutech Expert CTS ™ Expert CTS Speci cations Conductivity Range 0.00 to 20.00 mS 10 µS below 2.00 mS, Resolution 0.10 mS above 2.00 mS Easy-to-read Relative Accuracy ±2 % full scale ±...
  • Page 2 Operating Instructions For Expert CTS Conditioning Before First Use Menu (To Change Settings) 1. Remove the transparent cap and add 20 mm of tap water (approximately ½ full). To reset the calibration to factory default condition: 2. Recap the Expert CTS tester and soak for at least 15 minutes. 3.