f.
The installation site and material must fully support the weight of the product.
g. Only use a dry cloth to clean the camera. If there is dirt that is difficult to remove wipe
gently with a mild detergent. Never use strong or abrasive detergents.
h. The included 24VAC at 3A power supply or approved equivalent must be used. Using
a DC or other incorrect power supply will damage the camera.
i.
Only qualified installers are allowed to install, test and disassemble the camera.
j.
The camera is a low voltage product. If installed outdoors proper safety and lightning
grounding are required.
k. Before installing be sure the grounding, wiring, input power, voltage, DIP switches,
communication protocol and baud rate are correctly set prior to powering up and
using.

4. CAMERA SETUP

System Setup DIP Switch SW1
Alarm Terminal 8P
Aux. Switch 4P
Address Set Up
See Appendix A for DIP Switch SW2 configurations for camera addresses.

Alarm Signal

Alarm Relay Output "AUX1"
Alarm Relay Output "AUX2
Alarm Input GND
Alarm input signal -7
v1.2 3/2/11
1, 2, 3, 4, 5, 6, 7 = Alarm Input Signal
AUX1, AUX2 = Auxiliary Equipment
GND = Alarm Input Grounding
4
Dome Address DIP Switch SW2
RS485 Terminal 2P
AC24V Power 1P
120Ω Resistance Short-Circuit