8.1. Preliminary remarks on installation

Remember that:
The installation must be performed by qualified personnel;
All local and national laws and European Standards must be complied with when installing and using the product.
In Italy the reference is the standard UNI 10683;
In the case of installation in condominiums it is necessary an offer with positive recommendation of the
administrator;
In the case of installation in public places, check and comply with local regulations for these installations.
The product is designed to operate in all weather conditions. In case of special conditions, as strong wind, safety
systems may intervene forcing the switch off of the product.
Some indications of a general nature are given below, which do not replace the checking against the local standards
and do not bring any liability concerning the installer's work.

8.2. Checking the suitability of the installation room

The volume of the room must be greater than that indicated in the technical table
The floor must be able to support the weight of the product and its accessories* (see the note in the paragraph
on heat protection)
Make sure that the product is levelled
Do not install in rooms where there is a risk of fire or explosion.
In Italy, check compatibility pursuant to UNI 10683 and UNI 7129 in the presence of gas products.

8.3. Heat protection and safety distances

All the surfaces of the building adjacent to the product must be protected against overheating.
The insulation measures to be taken depend on the type of surfaces present.
The product must be installed in accordance with the following safety conditions:
Minimum distance from any combustible materials: see the declaration of performance on the website
In the case of installation with a wall made of wood or other flammable material, the smoke exhaust pipe must be
adequately insulated.
In the case of installation on a floor made of flammable and/or combustive material or with an insufficient load-bearing
capacity, it is advisable to place the product on a load distribution plate.