Warning
Make sure that the brackets are locked
together by the locating pins. Failure to
properly engage the brackets will cre-
ate an unsafe installation that may
cause equipment damage or personal
injury.
F.
Two people are needed to mount the
ULTROpure on the wall bracket. With one per-
son facing the right side or the unit and one
person facing the left side of the unit, each
person places one hand on the bottom edge
of the ULTROpure. Use the other hand to
steady the unit about halfway up the unit. Lift
and tilt the unit and place it over the angle
iron wall bracket so that the mating bracket is
above the locating pins. Press the unit toward
the wall and slowly slide it down the wall until
the two brackets lock together.
G.
Ensure the brackets lock together. The line
scribed in step D should be equal with the top
of the ULTROpure. If this is not the case,
repeat step F.
H.
Install 1/4" fasteners to further secure the
ULTROpure on the wall. These fasteners are
to be installed in the upper cabinet. The holes
are located on the upper right-hand and left-
hand corners of the back panel. (Locations
indicated by point A on Figure B, page 10.)
I.
Refer to your storage reservoir ownerʼs manu-
al and mount the reservoir. Do not connect to
the ULTROpure at this time.