Thermo Scientific VersaCool User Manual
Thermo Scientific VersaCool User Manual

Thermo Scientific VersaCool User Manual

Refrigerated bath circulator

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 77

Quick Links

V ersa C ool
Refrigerated Bath Circulator
Manual Part Number U01265, April 4, 2016
Multilingual Setup Wizards
Multilingual Essential Safety Instructions
Installation
Operation
Preventive Maintenance
Troubleshooting

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VersaCool and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Thermo Scientific VersaCool

  • Page 1 V ersa C ool Refrigerated Bath Circulator Manual Part Number U01265, April 4, 2016 Multilingual Setup Wizards Multilingual Essential Safety Instructions Installation Operation Preventive Maintenance Troubleshooting...
  • Page 3: Table Of Contents

    Nitrogen Purge........................3-11 Filling Requirements ......................3-12 Draining ..........................3-12 Chapter 4 Operation ........................... 4-1 VersaCool Touchscreen ......................4-1 Initial Start Up ........................4-2 Daily Start Up........................4-2 Changing a Set Point ......................4-4 Shut Down ........................... 4-4 Touchscreen Displays ......................4-5 Viewing/Changing a Settings Screen ..................
  • Page 4 Testing the Safety Features ....................6-4 Appendix A AC Serial Communications Protocol ................A-1 Appendix B Analog IO ........................... B-1 Appendix C Mobile Communications....................C-1 Appendix D GNU LESSER GENERAL PUBLIC LICENSE .................D-1 Declaration of Conformity Warranty VersaCool Thermo Scientific...
  • Page 5: Preface

    Thermo Fisher Scientific has contracted with one or more recycling/ disposal companies in each EU Member State, dispose of or recycle this product through them. Further information on Thermo Fisher Scientific’s compliance with these Directives is available at: www.thermoscientific.com/WEEERoHS Thermo Scientific VersaCool...
  • Page 6: Unpacking

    Sample Nameplate Newington, NH 03801 U.S.A. (800)258-0830/(603)436-9444 LISTED LABORATORY BOM#: xxxxxxxxx Dev: No EQUIPMENT S/N: xxxxxxxxxx IIIIIIIIIIII IIIIIIIIII IIIIIIIIII IIIIII IIII III 10 LB R134A x.xxKG HI xx.xBAR LO xx.xBAR x.xxOZ xxxPSI xxxPSI VersaCool Thermo Scientific...
  • Page 7: Feedback

    Tel: (800) 258-0830 Tel : (800) 258-0830 or (603) 436-9444 Sales: 8:00 am to 5:00 pm Fax : (603) 436-8411 Service and Support: 8:00 am to 6:00 pm Monday through Friday (Eastern Time) www.thermoscientific.com/tc Fax: (603) 436-8411 service.tc.us@thermofisher.com Thermo Scientific VersaCool...
  • Page 8 Preface VersaCool Thermo Scientific...
  • Page 9: Chapter 1 Safety

    The bath's construction provides protection against the risk of electrical shock by grounding appropriate metal parts. The protection will not function unless the power cord is connected to a properly grounded outlet. It is the user's responsibility to assure a proper ground connection is provided. Thermo Scientific VersaCool...
  • Page 10 Do not use automotive antifreeze. Commercial antifreeze contains silicates, or any Organic Acid Technologies (OATs), that can damage the pump seals. Use of automotive antifreeze voids the manufacturer’s warranty. Never use corrosive fluids with this bath. Use of these fluids also voids the manufacturer’s warranty. VersaCool Thermo Scientific...
  • Page 11: Personal Protective Equipment

    We do recommend wearing eye protection and gloves. Training The user must review and understand all the sections in this manual before operating the bath. Thermo Scientific VersaCool...
  • Page 60 Chapter 1 Safety VersaCool Thermo Scientific...
  • Page 61: Setup Wizards

    • • After the power cord is connected place the circuit protector located on the rear of the bath to the I position. • Then the Setup Wizard Display appears. • The touchscreen momentarily displays: W -1 Thermo Scientific VersaCool...
  • Page 62 • is replaced by . Touch when you are ready to stop the bath. • After starting check all plumbing connections for leaks. • Adjust the High Temperature Cutout (HTC) safety device, refer to the manual. VERSACOOL Thermo Scientific...
  • Page 63 Befüllen Sie den Behälter langsam auf eine Höhe zwischen den Markierungen MIN und MAX. • Wenn das Stromkabel angeschlossen ist, stellen Sie den Stromkreisschutz auf der Rückseite des Bads auf die Position I. • Auf dem Touchscreen erscheint kurz: • Anschließend wird der Einrichtungs-Assistent eingeblendet. Thermo Scientific VersaCool W -3...
  • Page 64 Sie die Einstellungen des Bads anpassen möchten. • wird durch ersetzt. Berühren Sie , wenn Sie das Bad anhalten wollen. • Überprüfen Sie nach dem Starten alle Wasseranschlüsse auf undichte Stellen. • Stellen Sie den Übertemperaturschutz (HTC) ein; siehe Handbuch. Thermo Scientific W -4 VersaCool...
  • Page 65 Remplissez doucement le réservoir jusqu’à ce que le niveau soit compris entre les lignes de remplissage MIN et MAX. • Après connexion du câble électrique, placez le dispositif de protection des circuits sur la position I. • L’écran tactile affiche temporairement : • Puis l’écran de l’Assistant de configuration apparaît. VersaCool W -5 Thermo Scientific...
  • Page 66 • Après le démarrage, vérifier tous les raccordements de tuyauterie à la recherche d’éventuelles fuites. • Régler le dispositif de sécurité du point de coupure haute température (HTC). Se reporter au manuel d’utilisation. VersaCool W -6 Thermo Scientific...
  • Page 67 Después de conectar el cable de alimentación, coloque el protector de circuito, situado en la parte trasera del baño, en la posición de encendido I. • En la pantalla táctil se mostrará brevemente: • Después, aparecerá el asistente de instalación. VersaCool W -7 Thermo Scientific...
  • Page 68 • Una vez puesta en marcha la unidad, revise todas las conexiones de fontanería para detectar posibles fugas. • Ajuste el corte de temperatura alta (HTC) del dispositivo de seguridad; consulte el manual. W -8 Thermo Scientific VersaCool...
  • Page 69 Dopo aver collegato il cavo di alimentazione, portare la protezione di circuito posta sul lato posteriore del bagno in posizione I. • Sullo schermo touchscreen compare • Viene dunque visualizzata la schermata della per qualche secondo: configurazione guidata. VersaCool W -9 Thermo Scientific...
  • Page 70 è pronti per arrestare il bagno. • Dopo l'avvio, controllare tutti i collegamenti dei tubi per escludere eventuali perdite. • Regolare il dispositivo di sicurezza HTC (High Temperature Cutout). Fare riferimento al manuale. W -10 VersaCool Thermo Scientific...
  • Page 71 Vul het reservoir langzaam tot een niveau tussen de vullijn MIN en de juiste vullijn MAX. Plaats de circuitbeveiliging aan de achterkant van het bad in de I-positie als de voedingskabel • is aangesloten. • Op het scherm ziet u nu: • Daarna verschijnt het display voor de installatiewizard. W -11 Thermo Scientific VersaCool...
  • Page 72 • wordt vervangen door . Raak aan als u het bad wilt stoppen. • Controleer na de start alle leidingaansluitingen op lekken. • Pas het HTC-veiligheidsapparaat (Uitschakeling bij Hoge Temperaturen) aan, raadpleeg hiervoor de handleiding. Thermo Scientific W -12 VersaCool...
  • Page 73: Chapter 2 General Information

    General Information Chapter 2 General Information Description All Thermo Scientific V ersaCool Refrigerated Bath Circulators can pump to an external system. All have a digital display and easy-to-use touchscreen, five programmable set point temperatures, acoustic and optical alarms, and offer adjustable high temperature protection.
  • Page 74: Specifications

    Chapter 2 General Information Specifications VersaCool Process Fluid Temperature °C -20 to 150 Range °F -4 to 302 Ambient Temperature °C 10 to 40 Range °F 50 to 104 Internal Bath Stability °C Water ±0.03 EG/Water ±0.06 PG/Water ±0.05 Cooling Capacity watts...
  • Page 75 • Thermo Fisher Scientific reserves the right to change specifications without notice. Pumping Capacity, Water mBar 1400 Set Point 20°C 1200 Pump Speed A = 100% 1000 B = 80% C = 60% D = 40% 10.0 12.0 14.0 16.0 lpm Flow Thermo Scientific VersaCool...
  • Page 76 D = 56.9% E = 40.0% 10.0 Flow Pumping Capacity, 50/50 PG/Water mBar 1000 Set Point -10°C Pump Speed A = 100% B = 89.3% C = 78.4% D = 67.7% E = 56.9% F = 40.0% Flow VersaCool Thermo Scientific...
  • Page 77 Time to Temperature, Water Max Fill Pump 100% A = 230V B = 208V C = 200V D = 115V E = 100V Time (Minutes) Time to Temperature, Water Max Fill Pump 100% All voltages Time (Minutes) Thermo Scientific VersaCool...
  • Page 78 Time to Temperature, EG/Water 50/50 Max Fill Pump 100% A = 230V B = 208V C = 200V D = 115V E = 100V Time (Minutes) Time to Temperature, EG/Water 50/50 Max Fill Pump 100% All voltages Time (Minutes) VersaCool Thermo Scientific...
  • Page 79 Time to Temperature, PG/Water 50/50 Max Fill Pump 100% A = 230V B = 208V C = 200V D = 115V E = 100V Time (Minutes) Time to Temperature, PG/Water 50/50 Max Fill Pump 100% All voltages Time (Minutes) Thermo Scientific VersaCool...
  • Page 80 C = 200V D = 115V E = 100V Time (Minutes) Time to Temperature, Sil 200 Max Fill Pump 100% A = 230V B = 208V C = 200V D = 115V E = 100V Time (Minutes) VersaCool Thermo Scientific...
  • Page 81 Chapter 2 General Information centimeters inches 47.4 52.9 " " " 20.6 " 25.9 " " " " 44.5 " 33.8 " 25.5 " Thermo Scientific VersaCool...
  • Page 82 11.8 " 53.7 " 58.5 " Shipping crate dimensions: H = 78.11cm / 30.75” W = 38.74cm / 15.25” D = 78.11cm / 30.75” Shipping weight = 46.3kg / 102lbs 46.6 38.6 " " 52.3 " 2-10 VersaCool Thermo Scientific...
  • Page 83: Chapter 3 Installation

    12”, open on the other side and 6” in the rear. Minimum Clearance A = 6" (15.2 cm) B = 0" B = 12" (30.5 cm) for Sil Oil above 125°C and 35°C ambient or above C = Must be open Thermo Scientific VersaCool...
  • Page 84: Electrical Requirements

    Note Before inserting the electrical cord into the connection ensure the circuit protector is in the O (off) position. Once the cord is connected to the bath, connect the other end to the main power source. VersaCool Thermo Scientific...
  • Page 85: Connectivity

    PLC. See Appendix B for additional information. Auto Refill Indicates the location of the connection for the optional auto refill accessory. Thermo Scientific VersaCool...
  • Page 86: Lid Reversal/Removal

    Mobile Communications The VersaCool Mobile App can use any iOS or Android smart phone or tablet to control and monitor up to seven VersaCool baths. Mobile communications is enabled when the circuit protector on the rear of the bath is in the I position. See Appendix C for additional information.
  • Page 87: External Circulation

    ½˝ MNPT hose barbs used primarily with quick disconnects. Note When not using external circulation the plumbing connections must be capped. Note To prevent damage to the bath's plumbing, use a 19 mm backing wrench when removing/ installing the external connections. Thermo Scientific VersaCool...
  • Page 88: Approved Fluids

    The primary risks of using untested and untreated tap water are corrosion caused by an out of range pH value and/or the concentration of dissolved solids, and those dissolved solids precipitating out of solution and forming scale. VersaCool Thermo Scientific...
  • Page 89 Distilled water is sterile Distilled and DI water need to be tested Distilled and DI water must be purchased or require specialized equipment to produce on site Deionizing does not guarantee sterility Thermo Scientific VersaCool...
  • Page 90 Can become corrosive without inhibitor Sterile (PG is Less toxic/safer to use, easier to dispose pH needs to be maintained to prevent corrosion of than EG) Toxic - needs to be handled and disposed of with care VersaCool Thermo Scientific...
  • Page 91: Additional Fluid Information

    In order to dry the oil, operate the bath at 100°C for one hour and then at 105°C for another hour. Clean and dry the reservoir and covers, especially gable covers. Any item placed in the reservoir must also be dry. Vacuum out reservoir, drain line and process lines. Thermo Scientific VersaCool...
  • Page 92: Tubing Requirements

    M16 - to - 1/4" NPT (M) M16 - to - 1/2" NPT (M) 8mm Hose Barb 12mm Hose Barb 1/4" Hose Barb 1/2" Hose Barb We highly recommend using foam rubber insulation on the tubing and the fittings. 3-10 VersaCool Thermo Scientific...
  • Page 93: Optional Auto Refill

    Installation Metal tubing Thermo Scientific metal tubing (stainless steel insulated) offers a particularly high degree of safety and is suitable for both low and high temperatures/liquids. The metal tubing is attached directly to the plumbing connections, gaskets are not required.
  • Page 94: Filling Requirements

    • Use a wet-vac on the drain connection to remove 100% of the process fluid. • When the flow stops close the drain plug. 3-12 VersaCool Thermo Scientific...
  • Page 95: Chapter 4 Operation

    Chapter 6 Troubleshooting. Place the circuit protector located on the rear of the bath to the I position. • • The touchscreen momentarily displays: Loading..Note The bath may “click” as it loads. Thermo Scientific VersaCool...
  • Page 96 This icon indicates the heater is on, it flashes when the heater is cycling on and off. This icon indicates the refrigeration is on. This icon indicates the timer, used to start/stop the bath at a specific time, is enabled. This icon indicates a connectivity option is enabled. VersaCool Thermo Scientific...
  • Page 97 When keypad and keyboard are used always appear at the bottom of the display. You must touch either to save the change, or touch to not save the change, in order to return to the previous screen. Thermo Scientific VersaCool...
  • Page 98: Changing A Set Point

    Touch to return to the Power touchscreen. For set point ranges and how to change the five preset set points refer to Viewing/Changing a Home Screen in this chapter. VersaCool Thermo Scientific...
  • Page 99: Touchscreen Displays

    Auto Restart Settings Units Language Resolution Sleep Mode Name Home Set Points Alarms Fluid Type Connectivity Data Logging Data Transfer Auto Refill Control Probe Pump Speed Charting Program Service Configuration Calibration Run Time Diagnostics Error Message Factory Reset Thermo Scientific VersaCool...
  • Page 100: Viewing/Changing A Settings Screen

    , touch it to remove the four icons. YYYY Date July 2015 If desired, touch the up arrow, , to display the four icons. Use the Time screen to view/ change the time and format. MINS FORMAT Time VersaCool Thermo Scientific...
  • Page 101 Japanese • French • Spanish • German The factory default is English. Use the Resolution screen to change the displayed temperature resolution, 0.1 or 0.01. The selected resolution is highlighted in green. The factory default is 0.1. Thermo Scientific VersaCool...
  • Page 102 OK. Reenter the password to confirm and then touch OK again. To open the bath touch Open and enter the password. To re-lock the bath touch Locked and enter the password. If you forget your password call us with the VersaCool’s serial number. Use the Timer screen to set and Current Time: xx:xx:xx enable/disable the timer.
  • Page 103 P = 5.0, I = 0.30 and D = 0.00 Use the Name screen to name your bath. There is a 20 character limit. The name identifies the bath when downloading files. The default is VersaCool 1. Thermo Scientific VersaCool...
  • Page 104: Viewing/Changing A Home Screen

    20.5°C, set the RTA to -0.5°C. After you enter an RTA value allow the display to stabilize before verifying the bath temperature. If display accuracy is required, we recommend repeating this procedure at various set point temperatures and on a regular basis. 4-10 VersaCool Thermo Scientific...
  • Page 105 Touching Yes brings up the current set point screen with a keypad to input the new set point. Touching No returns the Fluid Type screen. Note With Sil 200, heater power is reduced to 60% when connected to 230V. 4-11 Thermo Scientific VersaCool...
  • Page 106 Note When running a program the set point value changes in order to meet the program’s step time to temperature parameters. Touch the Full Screen icon enlarge the screen. Touch to return to the above display. 4-12 VersaCool Thermo Scientific...
  • Page 107 Changing the start temp for the following step will result in an error message when the program is saved. Next enter the TIME. The maximum duration for each STEP is 999 minutes (~16.5 hours). 4-13 Thermo Scientific VersaCool...
  • Page 108 Touch RUN to start the program and bring up the Program Display. Note The program will not start until the process fluid temperature is at the START TEMP ± the Variance. Touch Full Screen to enlarge the display. 4-14 VersaCool Thermo Scientific...
  • Page 109 Parity: Odd or Even Data Bits: 7 or 8 Stop Bits: 1 or 2 Addresses: 1 to 99 (RS 485 only) Refer to Appendix A for serial communication protocol information. Refer to Appendix B for details on Analog IO. 4-15 Thermo Scientific VersaCool...
  • Page 110 (121 includes the Data Point at “Time = Zero”) Use the Data Transfer screen to upload/download data files between the bath and a storage device. Uploading/downloading includes data recording, error logs, charting data and ramp data. Touchscreen firmware upgrades can also be uploaded. 4-16 VersaCool Thermo Scientific...
  • Page 111 The factory default is Internal. Selecting Remote allows you to set fluid temperature limits Above and Below the set point. With limit on the VersaCool will only operate within the set range regardless of what is happening at the external application. This is a...
  • Page 112: Viewing/Changing A Service Screen

    • Touch Sp x again and enter the other calibration temperature, repeat the procedure. • Once both points are entered, touch to complete the calibration. Contact us if you need to calibrate the Outlet temperature sensor. 4-18 VersaCool Thermo Scientific...
  • Page 113 Use the Diagnostics screen to view component status. This information cannot be changed. Use the Error Messages screen to view component error messages. This information cannot be changed although you can clear all the messages by touching Clear Screen. 4-19 Thermo Scientific VersaCool...
  • Page 114 PID values and the pump speed back to their factory settings. Touch RESET and then Confirm or Cancel the procedure. This screen appears once the reset is complete. 4-20 VersaCool Thermo Scientific...
  • Page 115: High Temperature Cutout

    To restart the bath press the black reset ring surrounding the red dial. If Auto Restart is enabled the bath restarts, if disabled use the Daily Start Up procedure. Note We recommend periodically rechecking operation or if the bath is moved. 4-21 Thermo Scientific VersaCool...
  • Page 116 Chapter 4 Operation 4-22 VersaCool Thermo Scientific...
  • Page 117: Preventive Maintenance

    Switch off the bath circulator and unplug the power cord. Clean the fins with compressed air. Hoses Inspect and tighten the external hoses and clamps daily. Electrical Power Cord Ensure any replacement cord is properly rated. Thermo Scientific VersaCool...
  • Page 118: Cleaning

    Apply these substances according to the manufacturer's recommendations. To clean the touchscreen use a microfiber cloth. For dirtier screens add a small amount of plain water (soap is not necessary). VersaCool Thermo Scientific...
  • Page 119: Chapter 6 Troubleshooting

    Once the cause of the shut down is identified and corrected, restart the bath. If the cause of the fault was not corrected the message will reappear. Thermo Scientific VersaCool...
  • Page 120 RA RTD Short refrigeration temp sensor short RA RTD Temp Fault check voltage supply the refrigeration may need servicing HPC Fault high pressure protection limit exceeded check for obstructions to air flow the refrigeration may need servicing VersaCool Thermo Scientific...
  • Page 121: Checklist

    Remote temperature probe selected but there is no probe attached to the bath. • Attach a remote probe or select the internal temperature sensor. All set points display 0°C • Cycle the bath's circuit protector. continued on next page Thermo Scientific VersaCool...
  • Page 122 If it is on ensure Analog IO is not enabled, . You cannot save a changes using the touchscreen if Analog IO is enabled. Please contact Thermo Fisher Scientific Sales Service and Customer Support if you need any additional information, see inside cover for contact instructions. VersaCool Thermo Scientific...
  • Page 123: Testing The Safety Features

    Remove the tool and then clear the error message. Repeat the procedure using the other round opening. If the message does not appear or the bath does not shut down, or the message does not clear, have the bath checked by a qualified technician. Thermo Scientific VersaCool...
  • Page 124 Drain the reservoir to below the max level mark and then clear the error message. If the message does not appear or the bath does not shut down, or the message does not clear, have the bath checked by a qualified technician. VersaCool Thermo Scientific...
  • Page 125: Appendix Aac Serial Communications Protocol

    A binary value 0 or 1 (0 = Off, FALSE or Disable(d); 1 = On, TRUE or Enable(d)). [CR] Carriage return – used as the termination character. Text representing the units associated with a value. A value that can be requested in a read command or sent as part of a set command. Thermo Scientific VersaCool...
  • Page 126 [V]C or F Read External RTA Preset 3 RERTA3 [V]C or F Read External RTA Preset 4 RERTA4 [V]C or F Read External RTA Preset 5 RERTA5 [V]C or F * see Possible Response Messages on page A-5. VersaCool Thermo Scientific...
  • Page 127 [V] V is 0=H O, 1=EG/H 2=PG/H O, 3=SIL 180, 4=SIL200 Read Firmware Version RVER Read Firmware Checksum RSUM Read Unit Fault Status RUFS [V1, V2 , V3, V4] See page A-4 * see Possible Response Messages on page A-5. Thermo Scientific VersaCool...
  • Page 128 Set Internal Control on Outlet Sensor SINTCTL [V] V=1 Internal Sensor, V=2 Outlet Sensor Set External Sensor Enabled SE [B] Set Auto Restart Enabled SAR [B] Set Pump Speed SPS [V] Set Unit Fault Status (clear errors) SUFS VersaCool Thermo Scientific...
  • Page 129 Auto Refill Timeout warning min step out of range warning B2 - B0 0 (reserved) Bath on Bath Faulted Pump Relay on Compressor Relay on Heating B2 - B0 0 (reserved) Thermo Scientific VersaCool...
  • Page 130 For a small set of discrete values like 1/0 (on/off); C/F "FAIL - Out of Range" For continuous settings such as a set point "FAIL - Password Required" Service: Must enter a password to use (e.g., set fan speed) "?" Unknown command or not implemented VersaCool Thermo Scientific...
  • Page 131: Appendix B Analog Io

    0.00 SetPoint application's needs. 0-10 V 0.00 4-20 mA High Temp 0.0°C The VersaCool supports three standard analog interface types and Custom Low Temp 0.0°C defaults using the following scaling: Volt mV 10mv/°C where 0V = 0°C, e.g., 50mV = +5°C, -100mV = -10°C Volt where 0v –...
  • Page 132 Any Fault Low Level Fault Low Level Fault Low Temperature Low Temperature High Temperature High Temperature Low Level Warning Low Level Warning Pump/Unit Shutdown Pump/Unit Shutdown RA Shutdown RA Shutdown Limit Fault Limit Fault Sensor Fault Sensor Fault VersaCool Thermo Scientific...
  • Page 133 Note 2: Default = 0-10VDC. These ranges are set by the user. Note 3: Connect to digital ground (pin 1) using a low resistance connection (gold contact relay). Note 4: Remote set point must be enabled, pin 13 Thermo Scientific VersaCool...
  • Page 134 Appendix B Analog IO When making your connection to the VersaCool Analog I/0 connector, in order to comply with the EMC directive: • Use a shielded I0 cable • Connect the remote end of the cable shield to earth ground.
  • Page 135: Appendix C Mobile Communications

    Appendix C Mobile Communications Appendix C Mobile Communications The VersaCool Mobile App can use any iOS or Android smart phone or tablet to control and monitor Mobile communications is enabled when the circuit protector on the up to seven VersaCool baths.
  • Page 136 Touching stops the bath. RUNNING Touch at the < VersaCool Mobile top-left of the display to return to the list of available baths. Use this list to activate/deactivate any of the displayed baths. See next page. VersaCool Thermo Scientific...
  • Page 137 Appendix C Mobile Communications Touch to bring up a list of all the baths currently connected to your mobile device, their reservoir fluid temperatures and their statuses. Touch to bring up a list of Icon Descriptions. Thermo Scientific VersaCool...
  • Page 138 Pinch and drag any portion of the chart to zoom in. Note The chart data is for display purposes only, it is not permanently stored on the mobile device. If you wish to access historical data you must download the data directly from the VersaCool (e.g. USB stick, communication port).
  • Page 139 Touch the displayed min or max temp value to bring up the keypad you use to make changes. If desired, touch and hold the bath's name to bring up the swatch used to change its color. Touch the desired color. Cancel your selection. Thermo Scientific VersaCool...
  • Page 140 Note Changing the name only affects how it appears on your mobile device. It does not change the name at the bath itself. VersaCool Thermo Scientific...
  • Page 141: Gnu Lesser General Public License

    To protect your rights, we need to make restrictions that forbid distributors to deny you these rights or to ask you to surrender these rights. These restrictions translate to certain responsibilities for you if you distribute copies of the library or if you modify it. Thermo Scientific VersaCool...
  • Page 142 The precise terms and conditions for copying, distribution and modification follow. Pay close attention to the difference between a "work based on the library" and a "work that uses the library". The former contains code derived from the library, whereas the latter must be combined with the library in order to run. VersaCool Thermo Scientific...
  • Page 143 (For example, a function in a library to compute square roots has a purpose that is entirely well-defined independent of the application. Therefore, Subsection 2d requires that any application-supplied function or table used by this function must be optional: if the application does not supply it, the square root function must still compute square roots.) Thermo Scientific VersaCool...
  • Page 144 (Executables containing this object code plus portions of the Library will still fall under Section 6.) VersaCool Thermo Scientific...
  • Page 145 Accompany the combined library with a copy of the same work based on the Library, uncombined with any other library facilities. This must be distributed under the terms of the Sections above. Thermo Scientific VersaCool...
  • Page 146 Each version is given a distinguishing version number. If the Library specifies a version number of this License which applies to it and "any later version", you have the option of following the terms and conditions either of that version or of any later version published by VersaCool Thermo Scientific...
  • Page 147 MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the GNU Lesser General Public License for more details. You should have received a copy of the GNU Lesser General Public License along with this library; if not, write to the Free Software Foundation, Inc., 51 Franklin Street, Fifth Floor, Boston, MA 02110-1301 USA Thermo Scientific VersaCool...
  • Page 148 Library into the modified Library’s header files unless such material is limited to (i) numerical parameters; (ii) data structure layouts; (iii) accessors; and (iv) small macros, templates and inline functions of five lines or less in length. Furthermore, you are not required to apply this additional permission to a modified version of the Library. VersaCool Thermo Scientific...
  • Page 149: Warranty

    Thermo Fisher Scientific warrants electronic components for 36 months, 24 months on all other components, from date of shipment the Thermo Scientific VersaCool Refrigerated Bath according to the following terms. Any part of the bath manufactured or supplied by Thermo Fisher Scientific and found in the reasonable judgment of Thermo Fisher to be defective in material or workmanship will be repaired at an authorized Thermo Fisher Repair Depot without charge for parts or labor.
  • Page 152 thermoscientific.com © 2016 Thermo Fisher Scientific Inc. All rights reserved. iOS is a registered trademark of Cisco. Android is a registered trademark of Google Inc. All other trade- marks are the property of Thermo Fisher Scientific Inc. and its subsidiaries. Specifications, terms and pricing are subject to change. Not all products are available in all countries.

Table of Contents