Volvo EPA2007 D13F Reference Manual page 152

Table of Contents

Advertisement

146 BASIC SERVICE
6. Install and tighten the V-band clamp that joins the outlet module to the exhaust pipe.
7. Secure the DPF bracket to the chassis frame bracket and tighten all fasteners to
specification.
8. Remove the transmission jack from under the assembly.
9. Install the pressure differential sensor tube that connects to the outlet module and
tighten fitting to specification.
Note: A high-temperature anti-seizing compound should always be applied to the
threads of the sensors, plugs and fittings in the exhaust system to avoid component
seizure or corrosion.
10. Install the lines and sensors connecting the various modules to each other.
Refer to torque specifications for the V-band clamp screws, lines and sensors in the
SPECIFICATIONS section of this manual
11. Install the fairing (if equipped), braces and steps that were removed to permit
access.
12. Using Premium Tech Tool (PTT), ensure all soot trigger levels are reset back to
zero.
W2033382