9. Perform the following steps to align the DPF muffler into final position on the
muffler stanchion:
Align the muffler inlet with the exhaust elbow.
Align the muffler upper supporting bracket to the stanchion and install the bolts
loose.
Loosely install the upper supporting band clamp with attached bracket and install
bracket bolts into the stanchion.
Loosely install the lower supporting band clamp.
10. With all components aligned, install and secure the lower V-band clamp at the
inlet side of the muffler.
11. Install the heat shield onto the DPF muffler.
12. Secure all fasteners and clamps that connect the DPF muffler to the stanchion.
Tighten all clamps and muffler fasteners according to specification.
13. Disconnect the lifting device and remove the lifting chain from the muffler.
14. Reconnect the harness connectors for all temperature and pressure differential
sensors on the DPF muffler.
15. Locate torque specifications for the V-band clamp screws, lines and sensors in the
SPECIFICATIONS section of this manual.
16. Using the Premium Tech Tool, (PTT) ensure all soot trigger levels are reset
back to zero.
BASIC SERVICE 151