  • Page 1 Compact Digital Infrared Wireless Conference System  Installation and Operating Manual V 1.1...
  • Page 2 To protect your hearing avoid high pressure level on earphones. Adjust to a lower and convenient level.  If any detailed information needed, please contact your local agent or TAIDEN service center in your region. Any feedback, advice and suggestion about the products is appreciated.
  • Page 3 TAIDEN Service Center. splashing and that no objects filled with liquids, such as 20. All TAIDEN products are guaranteed for definite time vases, shall be placed on the apparatus. (see the WARRANTY CARD for details) excluding the...
  • Page 4 Important Safety Instructions WARNING: To reduce the risk of electric shock, DO NOT expose units to rain or moisture. Attention: Installation should be performed by qualified service personnel only in accordance with the National Electrical or applicable local codes. Power Disconnect: Units with or without ON – OFF switch have power supplied to the unit whenever the power cord is inserted into the power source;...
  • Page 5 Lithium battery safety precautions  To change battery please power off and take off the battery immediately.  Keep the battery away from heat sources to prevent fire or explosion.  Do not use a battery that is leaking, deformed, discolored or overheats. ...
  • Page 6: Table Of Contents

    Contents Installation & User Guide ......................VI Chapter 1 System introduction ....................1 1.1 Overview ..................................1 1.2 Functions and features ..............................3 1.3 System technology ..............................4 1.3.1 Basic system concept ..............................4 1.3.2 IR radiation .................................. 4 1.3.3 Aspects of infrared signal transmission ........................4 1.3.4 Carriers and channels ..............................
  • Page 7: Installation & User Guide

    This manual is a comprehensive guide to the  Compact Digital Wireless Conference installation and operation of TAIDEN HCS-5335 series System Combo Unit Compact Digital Infrared Wireless Conference System. HCS-5335MA It includes detailed description of the function and Compact Digital IR Wireless Conference System...
  • Page 8: Chapter 1 System Introduction

    Chapter 1 System introduction 1.1 Overview TAIDEN extends its portfolio of wireless conferencing audio signals and tabletop/on-tripod installation of the solutions by launching a compact complement, new main unit, making the system an ideal solution for HCS-5335 series Digital Infrared Wireless Conference small to medium sized multipurpose rooms or historical System.
  • Page 9 The system is composed of one or more of the following:  Compact Digital Wireless Conference System Combo Unit HCS-5335MA Compact Digital IR Wireless Conference System Combo Unit (with digital IR transceiver)  Compact Digital IR Wireless Conference Unit HCS-5335AC Digital IR Wireless Chairman Unit (black, with battery) HCS-5335AD Digital IR Wireless Delegate Unit (black, with battery)
  • Page 10: Functions And Features

    1.2 Functions and features  Based on TAIDEN originated dirATC-digital infrared Audio Transmitting Control technologies  Digital infrared audio processing transmitting technologies ensure superb sound quality:  Freq. Response: 20 Hz to 20 kHz  S/N: >85 dBA  THD: <0.06% ...
  • Page 11: System Technology

    1.3.4 Carriers and channels wireless conference unit and converts the signals into TAIDEN HCS-5335 compact digital infrared wireless audio which is transmitted to the digital audio power conference system adopts 1~6 MHz wave band (IEC amplifier, or into control signals which are convert into 61603 BAND Ⅲ,Ⅳ), shown as figure 1.2..
  • Page 12: Chapter 2 Digital Ir Wireless Conference System Combo Unit

    Chapter 2 Digital IR Wireless Conference System Combo Unit 2.1 Overview 2.2 Functions and indications HCS-5335M Compact Digital Infrared Wireless Conference System Combo Unit is the heart of the HCS-5335 wireless conference system. Its audio, control and power signals all transmitted over a single Cat.5 cable from the highly-integrated main unit with infrared receiver and a built-in digital signal processor.
  • Page 13: Installation And Connection

    2.3 Installation and connection HCS-5335MA is tabletop mounted and it can also be Discussion and auto video tracking can be realized by fixed on HCS-5335ZJ stand. connecting the HCS-5335M to the Ethernet PoE switch HCS-5335M is highly-integrated main unit with infrared via a Cat.5 cable for communication with other network receiver and a built-in digital signal processor with its devices such as PC, web camera and HPA-160D/02...
  • Page 14: Web Server

    Web server can be used for configuration and control of the discussion units and tracking cameras by connecting HCS-5335M to PC via PoE switch. Operating environment: Firefox, Chrome, or IE11 or higher. 2.4.1 Login and exit Search HCS-5335M with TAIDEN Device Discovery, as shown below: Figure2.4: search device How to enter Web server: ...
  • Page 15 Figure2.6: Web interface Note: Parameter settings take effect immediately; please exit the web page before the HCS-5335M powered off to save the configuration.
  • Page 16: Device Status

    2.4.2 Device Status Device Status includes “Device status” and “Predefined Position”. The left side of “Device status” is speaking list and microphone list, and the right side displays the current status of the devices. Figure2.7: Device status  Speaking List: display the quantity of active microphone and microphone ID; ...
  • Page 17  Dante output status: HCS-5335M has 4 Dante outputs: Dante1 for the mixed audio of MIC1 and MIC2, Dante2 for MIC1, Dante3 for MIC2 and Dante4 is null. The Dante Output displays dynamic level of Dante1, the gain can be adjusted (range: -30 to 0 dB) as well and click “DSP” can set the parameter of EQ and DRC (dynamic ratio compressor);...
  • Page 18  Predefined Position: set predefined position for every microphone. If the conference system is equipped with cameras, the system can realize automatic video tracking, i.e. display the image of the speaking participator to the displays (large screen, TV, and so on). Figure2.10: Predefined Position Microphone predefined position setup: 1....
  • Page 19: Device Settings

    2.4.3 Device Settings Setting the parameter of HCS-5335 system: Figure2.11: Device Settings  Device name: set the name of HCS-5335M Digital IR Wireless Conference Combo Unit;  IP Address: IP address of HCS-5335M;  Netmask;  Gateway;  DHCP: the IP address, netmask and gateway can be got automatically when power on if the DHCP is “ON”, and you can set them manually if DHCP is “OFF”.
  • Page 20: Chapter 3 Digital Infrared Wireless Conference Unit

    Chapter 3 Digital infrared wireless conference unit 3.1 Overview HCS-5335 series Compact Digital Infrared Wireless Conference Units are the basic devices for meeting participators, divided into delegate unit and chairman unit with priority features. Types: HCS-5335AC Digital IR Wireless Chairman Unit (black, with battery)
  • Page 21: Functions And Indicating

    3.2 Functions and indicating HCS-5335AC HCS-5335AD Back HCS-5335BD Figure 3.1 HCS-5335 series compact digital infrared wireless conference unit Figure 3.1: 1. . Priority button (for chairman unit only)  Turn on the microphone and all other active 5. Battery indicator...
  • Page 22: Precautions In Using

    3.3 Precautions in using 3.4 Operation  Avoid direct sunshine when using, otherwise it The operation of the chairman unit and the delegate unit may cause signal blocking. will be introduced in detail in this section. 3.4.1 The operation of delegate unit The Mic.
  • Page 23: Chapter 4 Accessories

    Web server: Operating environment: Firefox, Chrome, or IE11 or higher. User can input the IP address of the device (search by “TAIDEN Device Discovery”) in the web browser to log in the control interface, includes “Device status” and “System setting”: ...
  • Page 24 Figure4.2: Device status  System setting: display the information of HCS-5335CHG/04 Intelligent Charging Station, includes hardware version, Web version, and date of manufacture. User can set the device name, and if the “DHCP” is off, the IP address, netmask and gateway can be set as well. Figure4.3: System setting The conference units can also be upgraded in this interface: 1.
  • Page 25: Hcs-5335Zj Stand

    Weight: 3.7 kg  With two-color illuminated ring (green/red)  Color: black  Build-in windshield  It is standard stem microphone for HCS-5335 series Wireless Conference Unit  Color: silver/ black  Weight: 60 g Figure 4.6 MS16EGAS stem microphone ...
  • Page 26: Chapter 5 Technical Data

    Chapter 5 Technical data 5.1 System specification System performance Conforms to IEC 60914, the international standard for conference systems Transmission characteristics IR transmission wavelength: 870 nm Modulation frequency: 1 to 6MHz Protocol and modulation: DQPSK System environmental conditions Working conditions fixed/stationary/transportable Temperature range: - Transport: -40 °C to +70 °C - Operating: 0 °C to +45 °C...
  • Page 27: Compact Digital Infrared Wireless Main Unit

    5.2 Compact digital infrared wireless main unit Type HCS-5335MA Mains voltage PoE (802.3af standard) Power consumption Max. 10 W Mounting Tabletop Maximal number of conference ≤200 units units Communication area Approx. 8 m in radius (ceiling height: 4 m) Weighted signal-to-noise ratio >85 dBA Dynamic range >90 dB...
  • Page 28: Compact Digital Infrared Wireless Conference Unit

    5.3 Compact digital infrared wireless conference unit Type HCS-5335A HCS-5335B Voltage 3.7 V DC Max. 540 mA Current consumption 1 mA Standby current Approx. 18 hours (20% speaking, 80% listening) Operation time of battery √ Discussion Only HCS-5335AC Priority key Wavelength 870 nm DQPSK...
  • Page 29: Charging Device

    5.4 Charging Device Type HCS-5335CHG/04 Mains voltage 9 VDC,6 A(HCS-ADP9V6A) Power consumption Max. 50 W Charging Time Approx. 4 hours Charging Capacity 4 HCS-5335 conference units Power indicator LED indicator Charging indicator Dimensions (mm) Weight 0.4 kg Color Black...
  • Page 30 TAIDEN INDUSTRIAL CO., LTD. 6/F, Block B, Future Plaza, 6060 Qiaoxiang Rd, Nanshan District, Shenzhen,China P.C.: 518053 Copyright by TAIDEN Website: http://www.taiden.com Last Revision: 10/2018...