No.
Description
2157
External battery load is insuffi-
cient (Battery empty)
2158
External battery is under test
(Battery testing)
2159
External battery bad or defect
(Battery bad)
2160
Temperature out of range (Temp
> Range)
2163
External battery in recovery mode
(Battery recover)
2164
Hardware charger defect (HW Err
Charger )
2165
LIN detection defect (LIN defect) Device, General
2166
Charging not possible (No charg-
ing)
2167
Charging current too high (High
current)
2168
Float charge mode defect (Float
Chg.Err)
2169
Error during external battery test
(Bat. Test Error)
2170
Temperature measurement error
(Temp Meas.Err)
2172
GPS Module Error (GPS Modu-
leError)
2186
Error occurred on IO board (Error
IO board)
2187
>BLOCK 27 under voltage prot.
Vx (>BLOCK 27 Vx)
2188
27 under volt. Vx switched OFF
(27 Vx OFF)
2189
27 under volt. Vx is BLOCKED
(27 Vx BLOCKED)
2190
27 under volt. Vx is ACTIVE (27
Vx ACTIVE)
2191
27-1 under volt. Vx PICKUP (27-
1 Vx PU)
2192
27-1 under volt. Vx TRIP (27-1 Vx
TRIP)
2193
27-2 under volt. Vx PICKUP (27-
2 Vx PU)
2194
27-2 under volt. Vx TRIP (27-2 Vx
TRIP)
2195
>BLOCK 59 over voltage prot. Vx
(>BLOCK 59 Vx)
2196
59 over volt prot. Vx switched
OFF (59 Vx OFF)
2197
59 over voltage Vx is BLOCKED
(59 Vx BLOCKED)
2198
59 over voltage Vx is ACTIVE (59
Vx ACTIVE)
2199
59-1 over voltage Vx PICKUP
(59-1 Vx PU)
2200
59-1 over voltage Vx TRIP (59-1
Vx TRIP)
SIPROTEC, 7SC80, Manual
E50417-G1140-C486-A1, Release date 12.2011
Function
Type
Log Buffers
of In-
forma-
tion
Device, General
OUT
On
Off
Device, General
OUT
On
Off
Device, General
OUT
On
Off
Device, General
OUT
On
Off
Device, General
OUT
On
Off
Device, General
OUT
On
Off
OUT
On
Off
Device, General
OUT
On
Off
Device, General
OUT
On
Off
Device, General
OUT
On
Off
Device, General
OUT
On
Off
Device, General
OUT
On
Off
Device, General
OUT
On
Off
Device, General
OUT
On
*
Off
27/59 Vx
SP
On
*
Off
27/59 Vx
OUT
On
*
Off
27/59 Vx
OUT
On
On
Off
Off
27/59 Vx
OUT
On
*
Off
27/59 Vx
OUT
*
On
Off
27/59 Vx
OUT
*
on
27/59 Vx
OUT
*
On
Off
27/59 Vx
OUT
*
on
27/59 Vx
SP
On
*
Off
27/59 Vx
OUT
On
*
Off
27/59 Vx
OUT
On
On
Off
Off
27/59 Vx
OUT
On
*
Off
27/59 Vx
OUT
*
On
Off
27/59 Vx
OUT
*
on
Configurable in Matrix
*
LED
BO
LED
BO
LED
BO
*
LED
BO
LED
BO
*
LED
BO
LED
BO
LED
BO
LED
BO
LED
BO
LED
BO
LED
BO
*
LED
BO
*
LED
BO
*
LED BI
BO
*
LED
BO
*
LED
BO
*
LED
BO
*
LED
BO
m
LED
BO
*
LED
BO
m
LED
BO
*
LED BI
BO
*
LED
BO
*
LED
BO
*
LED
BO
*
LED
BO
m
LED
BO
Appendix
A.9 Information List
IEC 60870-5-103
311

Advertisement

Table of Contents
loading

Table of Contents