Remove Controller Canister - NetApp E Series Maintaining

Hide thumbs Also See for E Series:
Table of Contents

Advertisement

Maintaining EF300 and EF600 Hardware
Host interface cards
6. Select Recheck from the Recovery Guru, and confirm that the OK to remove field in the
Details area displays Yes, indicating that it is safe to remove this component.
After you finish
Go to

Remove controller canister

Remove controller canister
You remove the controller canister so you can replace the failed host interface card. When you
remove a controller canister, you must disconnect all cables. Then, you can slide the controller
canister out of the controller shelf.
Before you begin
You have labels to identify each cable that is connected to the controller canister.
You must have a #1 Phillips screwdriver.
You have an ESD wristband, or you have taken other antistatic precautions.
You have prepared a flat, static free work area.
Steps
1. Label each cable that is attached to the controller canister.
2. Disconnect all the cables from the controller canister.
3. If the HIC ports use SFP+ transceivers, remove them.
Depending on what type of HIC you are upgrading to, you might be able to reuse these SFPs.
4. Confirm that the Cache Active LED on the back of the controller is off.
5. Squeeze the handles on either side of the controller, and pull back until it releases from the
shelf.
6. Using two hands and the handles, slide the controller canister out of the shelf. When the front
of the controller is free of the enclosure, use two hands to pull it out completely.
.
Attention: To prevent degraded performance, do not
twist, fold, pinch, or step on the cables.
Attention: Always use two hands to support the
weight of a controller canister.