TANK-XM810
CPU_FAN1/SYS_FAN1/SYS_FAN2 Smart Fan Control [Auto Mode]
Use the CPU_FAN1/SYS_FAN1 Smart Fan Control option to configure the CPU Smart
Fan.
Manual Mode
Auto Mode
CPU_FAN1/SYS_FAN1/SYS_FAN2 start temperature
If the CPU/System temperature is between fan off and fan start, the fan speed change to
fan start PWM. To set a value, Use the + or – key to change the value or enter a decimal
number between 1 and 100.
CPU_FAN1/SYS_FAN1/SYS_FAN2 off temperature
If the CPU/System temperature is lower than the value set this option, the fan speed
change to be lowest. To set a value, Use the + or – key to change the value or enter a
decimal number between 1 and 100.
CPU_FAN1/SYS_FAN1/SYS_FAN2 start PWM
Use the CPU_FAN1/SYS_FAN1/SYS_FAN2 Start PWM option to set the PWM start
value. Use the + or – key to change the value or enter a decimal number between 1 and
100.
Auto mode fan slope PWM
Use the Auto mode fan slope PWM option to select the linear rate at which the PWM
mode increases with respect to an increase in temperature. Use the + or – key to change
the value or enter a decimal number between 1 and 8
The fan spins at the speed set in Manual Mode
settings.
D
The fan adjusts its speed using Auto Mode
EFAULT
settings.