Embedded system with 10th/11th generation intel core processor, two ddr4 slot, digital i/o, hdmi, dp, two gigabit ethernet, rs-232/422/485, rohs compliant (132 pages)
High performance fanless embedded system with intel core i5-4400e/ celeron 2000e processor, vga, hdmi, display port, 9-36v dc input and rohs compliant (89 pages)
Tank-6000-c226 series embedded s ystem s upports 22nm lga1155 intel xeon e3 / core i3 cpu, hdmi, vga, gbe, two usb 2.0, four usb 3.0, two com and rohs compliant (138 pages)
Embedded system with 4th generation intel core processor, vga, dvi-i, displayport, two gigabit ethernet, four usb 3.0, two usb 2.0, rs-232/422/485, rohs compliant (134 pages)
Embedded system with 2nd generation intel core desktop processor, vga, dvi-i, two gigabit ethernet, four usb 2.0, two usb 3.0, r s -232/422/485, rohs compliant (122 pages)
High performance fanles s embedded sys tem with intel 32nm cpu, on-board 2.0 gb ddr3 memory, hdmi, usb 3.0, gigabit lan, audio, 9v~36v dc input, rohs compliant (96 pages)
Fanless embedded system with intel celeron j6412 2.0ghz up to 2.6ghz, 4-core, tdp 10w, 8gb ddr4 pre-installed memory, 10v-28v dc, with rs-232, rs-232/422/485, usb 3.2, usb 2.0, hdmi, 2.5gbe lan and rohs (132 pages)
Industrial panel pc for 2nd/3rd generation intel core, pentium or celeron cpu, intel h61 express chipset, touchscreen, usb 3.0, dual gigabit lan supporting sfp fiber, ip 66 compliant front panel and rohs compliant (156 pages)
Flat bezel panel pc with intel celeron j1900 quad-core pcu, touchscreen, dual usb 3.0, dual gbe lan, rs-232, hd audio, wi-fi 802.11a/b/g/n/ac, ip 65 rating and rohs (130 pages)
Summary of Contents for IEI Technology TANK-XM810 Series
Page 1
MODEL: TANK-XM810 Series Embedded System with 10th/11th Generation Intel® Core™ Processor, Two DDR4 Slot, Digital I/O, HDMI, DP, Two Gigabit Ethernet, RS-232/422/485, RoHS Compliant User Manual Rev. 1.00 – May 20, 2022...
Page 2
TANK-XM810 Revisions Date Version Changes May 20, 2022 1.00 Initial release Page II...
Page 3
TANK-XM810 Copyright COPYRIGHT NOTICE The information in this document is subject to change without prior notice in order to improve reliability, design and function and does not represent a commitment on the part of the manufacturer. In no event will the manufacturer be liable for direct, indirect, special, incidental, or consequential damages arising out of the use or inability to use the product or documentation, even if advised of the possibility of such damages.
Page 4
TANK-XM810 Manual Conventions WARNING Warnings appear where overlooked details may cause damage to the equipment or result in personal injury. Warnings should be taken seriously. CAUTION Cautionary messages should be heeded to help reduce the chance of losing data or damaging the product. NOTE These messages inform the reader of essential but non-critical information.
TANK-XM810 Table of Contents 1 INTRODUCTION ......................1 1.1 O ........................2 VERVIEW 1.2 M ....................3 ODEL ARIATIONS 1.3 F ........................3 EATURES 1.4 T ..................4 ECHNICAL PECIFICATIONS 1.5 F ......................6 RONT ANEL 1.6 R ....................... 7 ANEL 1.7 P ....................
Page 6
TANK-XM810 3.7 A ....................32 VAILABLE RIVERS 3.7.1 Driver Download ..................... 32 3.8 M ......................34 AINTENANCE 3.8.1 Flash Descriptor Security Override Jumper ............ 34 4 SYSTEM MOTHERBOARD ..................36 4.1 O ........................ 37 VERVIEW 4.1.1 Layout ......................37 4.2 I ..............
Page 7
TANK-XM810 C.1 PEI B ..................... 56 ODES C.2 DXE B ....................56 ODES D HAZARDOUS MATERIALS DISCLOSURE ............57 D.1 R HS II D (2015/863/EU) ............... 58 IRECTIVE D.2 C HS ......................59 HINA Page VII...
Page 8
TANK-XM810 List of Figures Figure 1-1: TANK-XM810 Series ....................2 Figure 1-2: Front Panel ........................6 Figure 1-3: Rear Panel ........................7 Figure 1-4: Physical Dimensions ....................8 Figure 3-1: Remove the Cover .....................18 Figure 3-2: Take out the motherboard ..................18 Figure 3-3: CPU Installation ......................19...
Q470 chipset, and has two 260-pin DDR4 SDRAM SO-DIMM slots supporting up to 64GB memory (8GB preinstalled). The TANK-XM810 Series includes one digital I/O port, one HDMI, one DP, two GbE LAN, six USB 3.2 Gen 1, two USB 2.0, two RS-232/422/485 and four RS-232 connectors.
TANK-XM810 1.2 Model Variations The model variations of the TANK-XM810 Series are listed below. Model No. Intel® Core™ i3-10320 3.8GHz TANK-XM810-i3BC-R10 (up to 4.6GHz, 4-core, TDP 65W) Intel® Core™ i3-10320 3.8GHz TANK-XM810-i5AC-R10 (up to 4.6GHz, 4-core, TDP 65W) Intel® Core™ i5-10500 3.1GHz TANK-XM810-i5BC-R10 (up to 4.5GHz, 6-core, TDP 65W)
TANK-XM810 1.4 Technical Specifications The TANK-XM810 Series technical specifications are listed in Table 1-2 Specifications Chassis Color Black C Dimensions (WxDxH) (mm) 230.6 x 256.04 x 76.2 System Fan Fanless Chassis Construction Extruded aluminum alloy Motherboard 10/11th Gen. Intel® Core™ CPU: Intel®...
TANK-XM810 Specifications Expansions 2 x 2280 M key (PCIe x2) Backplane Optional Power DC jack: 12 V~28 V DC Power Input Terminal block: 12 V~28 V DC Power Consumption 12V @ 8.8A (Intel ® Core™ i9-12900TE with 16GB memory) Remote Power 1 x 2-pin Reliability Mounting...
Electrostatic discharge (ESD) can cause serious damage to electronic components, including the TANK-XM810 Series. Dry climates are especially susceptible to ESD. It is therefore critical that whenever the TANK-XM810 Series or any other electrical component is handled, the following anti-static precautions are strictly adhered to.
If some of the components listed in the checklist below are missing, please do not proceed with the installation. Contact the IEI reseller or vendor you purchased the TANK-XM810 Series from or contact an IEI sales representative directly. To contact an IEI sales representative, please send an email to sales@ieiworld.com.
Page 22
TANK-XM810 Quantity Item and Part Number Image Standard 2-pin Terminal block 4-pin Terminal block Chassis screws The following table lists the optional items that can be purchased separately. Optional Wi-Fi module (P/N: EMB-WIFI-KIT02I3-R10) Page 12...
Page 25
TANK-XM810 Optional 3-Slot Chassis (P/N: TXC-XM81-3S-R10) 4-Slot Chassis (P/N: TXC-XM81-4S-R10) 4-Slot Chassis (Full-length graphics card support) (P/N: TXC-XM81-G1-R10) 6-Slot Chassis (Two Full-length graphics card support) (P/N: TXC-XM81-G2-R10) NOTE: 1.EMB-WIFI-KIT02I3-R10 needs to be used with TXIOB-XM81-A-R10. 2.TXCBP-XM81 series backplane needs to be used with TXC-XM81 series chassis Page 15...
Electric shock and personal injury might occur if the rear panel of the TANK-XM810 Series is opened while the power cord is still connected to an electrical outlet.
TANK-XM810 3.2 CPU /RAM/ Storage Installation To install the CPU /RAM/ Storage, please follow the steps below: Step 1: Remove the 6 screws on the side, and then remove the top cover (Figure 3-1). Figure 3-1: Remove the Cover Step 2: Remove the 11 spring screws on the motherboard, and then take out the motherboard (including the motherboard holder) (Figure 3-2).
TANK-XM810 Figure 3-3: CPU Installation Step 4: Place a thermal pad on the heat conductive block of CPU (Figure 3-4). Figure 3-4: CPU Thermal Pad Installation Step 5: Align the motherboard (together with the motherboard holder) with the 4 positioning rods on the 2 sides, place it on the heat sink, and lock the motherboard with 11 spring screws.
TANK-XM810 Figure 3-5: Motherboard Installation Step 6: Insert the memory into the motherboard memory slot and press it into place(Figure 3-6) Figure 3-6: RAM Installation Step 7: Remove the M.2 2280 reserved screws, install the M.2 2280 NVME card, and re-lock the fixing screws (Figure 3-7) Page 20...
TANK-XM810 Figure 3-7: M.2 Installation Step 8: Place the hard drive into the hard drive bracket and secure the HDD bracket and the hard drive with four screws (Figure 3-8) Page 21...
TANK-XM810 Figure 3-8: HDD Installation Step 9: Install the back cover. And lock the 6 screws on the side (Figure 3-9) Figure 3-9: Back Cover Installation 3.3 Mounting the System with Mounting Brackets To mount the embedded system onto a wall or some other surface using the two mounting brackets, please follow the steps below.
Insert four retention screws, three in each bracket, to secure the system to the wall. 3.4 External Peripheral Interface Connectors The TANK-XM810 Series has the following connectors. Detailed descriptions of the connectors can be found in the subsections below. ...
RS-232/422/485 3.4.1 AT/ATX Power Mode Selection The TANK-XM810 Series supports AT and ATX power modes. The setting can be made through the AT/ATX power mode switch on the external peripheral interface panel as shown below (Figure 3-11).. Figure 3-11: AT/ATX Power Mode Switch 3.4.2 SYS_FAN Connector...
TANK-XM810 Figure 3-12: SYS_FAN Connector 3.4.3 Digital Input / Output Connector The digital I/O connector provides programmable input and output for external devices. The pinouts for the digital I/O connector are listed in the table below (Table 3-1) (Figure 3-13). PIN NO.
Figure 3-16. Step 2: Align the connectors. Align the RJ-45 connector on the LAN cable with one of the RJ-45 connectors on the TANK-XM810 Series. See Figure 3-15. Figure 3-15: LAN Connection Step 3: Insert the LAN cable RJ-45 connector. Once aligned, gently insert the LAN cable RJ-45 connector into the on-board RJ-45 connector.
TANK-XM810 Figure 3-16: RJ-45 Ethernet Connector The RJ-45 Ethernet connector has two status LEDs, one green and one yellow. The green LED indicates activity on the port and the yellow LED indicates the port is linked. See Table 3-2 Activity/Link LED Speed LED DESCRIPTION STATUS...
TANK-XM810 Figure 3-18: Power Input Connector 3.4.8 DB-9 RS-232/422/485 Serial Port Connectors The system has two RS-232/422/485 & four RS232 serial port connectors. The pinouts for the serial ports are listed in the table below (Table 3-3) (Figure 3-19). PIN NO. RS232 RS422 RS485...
TANK-XM810 3.4.9 Remote Power Connector This remote power switch connector can be connected to an external switch for remote control of power on and off (Figure 3-20) Figure 3-20: Remote Power Connector 3.5 Powering On/Off the System WARNING: Make sure a power supply with the correct input voltage is being fed into the system.
TANK-XM810 Figure 3-21: Power Button 3.6 Power There are two power connectors on the rear panel. Power 1 connector is a 4-pin terminal block that supports ACC On signal. Power 2 connector is a DIN connector that can directly connect to a power adapter. The supported power input voltages are: ...
TANK-XM810 Figure 3-22: Power Connectors LED Indicator Description Standby mode. Power LED1 (Breathing Orange) Power-on mode. Power LED2 (Solid blue) Table 3-4: Power LED Indicators Description NOTE: The power LED turns off when the power cable is unplugged from the system.
TANK-XM810 3.7 Available Drivers All the drivers for the TANK-XM810 Series are available on IEI Resource Download Center (https://download.ieiworld.com). Type TANK-XM810 Series and press Enter to find all the relevant software, utilities, and documentation. Figure 3-23: IEI Resource Download Center 3.7.1 Driver Download...
Page 43
TANK-XM810 Step 3: Click the driver file name on the page and you will be prompted with the following window. You can download the entire ISO file ( ), or click the small arrow to find an individual driver and click the file name to download ( NOTE: To install software from the downloaded ISO image file in Windows 10 (or later), double-click the ISO file to mount it as a virtual drive to view...
TANK-XM810 3.8 Maintenance To configure the jumper settings, please follow the steps below. Step 1: Remove the top cover. See Figure 3-2. Step 2: Locate the jumper on the embedded motherboard. Step 3: Make the jumper settings in accordance with the settings described and defined in the following sections.
Page 45
TANK-XM810 Step 1: Before turning on the system power, short the Flash Descriptor Security Override jumper. Step 2: Update the BIOS and ME firmware, and then turn off the system power. Step 3: Remove the metal clip on the Flash Descriptor Security Override jumper or return to its default setting (open).
TANK-XM810 4.1 Overview This chapter details all the jumpers and connectors of the system motherboard. 4.1.1 Layout The figures below show all the connectors and jumpers of the system motherboard. Figure 4-1: System Motherboard (Front) Page 37...
TANK-XM810 4.2 Internal Peripheral Connectors The table below shows a list of the internal peripheral interface connectors on the system motherboard. Pinouts of these connectors can be found in the following sections. Connector Type Label Clear CMOS Switch 4-pin Switch J_CMOS1 Battery connector 2-pin header...
TANK-XM810 4.2.9 LAN LED Connector (LED_LAN1/LED_LAN2/LED_LAN3) PIN NO. DESCRIPTION PIN NO. DESCRIPTION VCC3V Table 4-10: LAN LED Connector 4.2.10 Battery Connector (BAT1) PIN NO. DESCRIPTION PIN NO. DESCRIPTION VBATT Table 4-11: Battery Connector (BAT1) 4.3 External Interface Panel Connectors The table below shows a list of the external interface panel connectors on the system motherboard.
Page 56
TANK-XM810 DECLARATION OF CONFORMITY This equipment is in conformity with the following EU directives: EMC Directive (2004/108/EC, 2014/30/EU) Low-Voltage Directive (2006/95/EC, 2014/35/EU) RoHS II Directive (2011/65/EU, 2015/863/EU) If the user modifies and/or install other devices in the equipment, the CE conformity declaration may no longer apply.
Page 57
TANK-XM810 Eesti [Estonian] IEI Integration Corp deklareerib seadme seadme vastavust direktiivi 2014/53/EÜ põhinõuetele ja nimetatud direktiivist tulenevatele teistele asjakohastele sätetele. Español [Spanish] IEI Integration Corp declara que el equipo cumple con los requisitos esenciales y cualesquiera otras disposiciones aplicables o exigibles de la Directiva 2014/53/EU. Ελληνική...
Page 58
TANK-XM810 Magyar [Hungarian] IEI Integration Corp nyilatkozom, hogy a berendezés megfelel a vonatkozó alapvetõ követelményeknek és az 2014/53/EU irányelv egyéb elõí rásainak. Polski [Polish] IEI Integration Corp oświadcza, że wyrobu jest zgodny z zasadniczymi wymogami oraz pozostałymi stosownymi postanowieniami Dyrektywy 2014/53/EU. Português [Portuguese] IEI Integration Corp declara que este equipamento está...
Page 59
TANK-XM810 FCC WARNING This equipment complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: This device may not cause harmful interference, and This device must accept any interference received, including interference that may cause undesired operation.
WARNING: The precautions outlined in this appendix should be strictly followed. Failure to follow these precautions may result in permanent damage to the TANK-XM810 Series. Please follow the safety precautions outlined in the sections that follow: B.1.1 General Safety Precautions Please ensure the following safety precautions are adhered to at all times.
TANK-XM810 Series and severe injury to the user. Electrostatic discharge (ESD) can cause serious damage to electronic components, including the TANK-XM810 Series. Dry climates are especially susceptible to ESD. It is therefore critical that whenever the TANK-XM810 Series is opened and any of the electrical components are handled, the following anti-static precautions are strictly adhered to.
The mark on electrical and electronic products only applies to the current European Union Member States. Please follow the national guidelines for electrical and electronic product disposal. B.2 Maintenance and Cleaning Precautions When maintaining or cleaning the TANK-XM810 Series, please follow the guidelines below. Page 53...
Some components in the TANK-XM810 Series may only be cleaned using a product specifically designed for the purpose. In such case, the product will be explicitly mentioned in the cleaning tips. Below is a list of items to use when cleaning the TANK-XM810 Series. ...
TANK-XM810 C.1 PEI Beep Codes Number of Beeps Description Memory not Installed Memory was installed twice (InstallPeiMemory routine in PEI Core called twice) Recovery started DXEIPL was not found DXE Core Firmware Volume was not found Recovery failed S3 Resume failed Reset PPI is not available C.2 DXE Beep Codes Number of Beeps...
TANK-XM810 D.1 RoHS II Directive (2015/863/EU) The details provided in this appendix are to ensure that the product is compliant with the RoHS II Directive (2015/863/EU). The table below acknowledges the presences of small quantities of certain substances in the product, and is applicable to RoHS II Directive (2015/863/EU).
Need help?
Do you have a question about the TANK-XM810 Series and is the answer not in the manual?
Questions and answers